Fault codes › Yaskawa Solectria › Solectria PVI 14/20TL

Yaskawa Solectria PVI-14-20TL Arc Protect

Code
Arc Protect
Vendor severity
Protection
Page
51
ID
fc:yaskawa-solectria-pvi-14-20tl-arcprotect
IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-pvi-14-20tl-arcprotect
Status
active
Also known as
Arc Protect, arcprotect, Yaskawa Solectria Arc Protect
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears by itself drafted · lead

Decoded

Reports arc fault detected; may indicate arc fault, arc detection board failure; look at arc fault detection board; do: board connector check, contact manufacturer service.

What can be behind Arc fault detected

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E050, ABB / FIMER PVS-60-TL E050, ABB / FIMER UNO-DM-3.3-5.0-PLUS E050, ABB / FIMER UNO-DM-6.0-PLUS E050
Canadian Solar
Canadian Solar 23-28KTL-CT ARC Protect, Canadian Solar 25-40K-T480GL01 ARC-FAULT, Canadian Solar 25-40KTL-GS-FL ARC-FAULT, Canadian Solar 50-66K-T480GL01 ARC-FAULT, Canadian Solar 50-66KTL-GS-FL ARC-FAULT, Canadian Solar 75-100K-T480GL02 ARC-FAULT
Solis
Solis 1P-4G-US ARC-FAULT, Solis RHI-1P-HV ARC-FAULT, Solis S5-GC ARC-FAULT, Solis S6-EH1P ARC-FAULT, Solis S6-EH2P ARC-FAULT, Solis S6-EH3P30-60K ARC-FAULT, Solis S6-EH3P75-150K ARC-FAULT, Solis S6-GC ARC-FAULT, Solis S6-GU ARC-FAULT
Yaskawa Solectria
Yaskawa Solectria PVI-25TL-R Arc Protect, Yaskawa Solectria PVI-TL Arc Protect, Yaskawa Solectria XGI-1500 CRIT-4

Same code in other families

Claims

defined_in

c1 drafted · lead PVI 14-20TL IOM DOCR-070351-G

has_event_class

c2 drafted · lead Fault (device stops or needs intervention)

from the Type column

reports

c3 verified · fact Arc fault detected

verified by: review-workflowverified on: 2026-10-23

indicates

c4 drafted · lead Arc fault

Internal DC-side arc is the first listed cause

c5 verified · fact Arc detection board failure

Second listed cause: the arc board itself is faulty

verified by: review-workflowverified on: 2026-10-23

affects

c6 drafted · lead Arc fault detection board

mitigated_by

c7 drafted · lead Board connector check

c8 drafted · lead Contact manufacturer service

Only if the alarm persists or inspection finds nothing

has_production_effect

c9 drafted · lead Trip (production stops)

has_recovery

c10 drafted · lead Auto-reset (clears by itself)

Can clear on its own within 10 minutes; if not, wiring inspection and then service

applies_to

c11 drafted · lead Solectria PVI 14-20TL