Solar Lattice

Symptom

Fan service life reached

ID
symptom:fan-end-of-life
IRI
https://solarlattice.org/kb/symptom/fan-end-of-life
Status
active
Also known as
Fan Life Reached, Fan service life has expired

On SGI-XTM central inverters this symptom shows up as a Fan Life Reached message on the user interface, and it is also written to the event log. In Modbus monitoring it is an informative alarm on bit 11, and the inverter keeps producing AC power while the alarm is active. Even though output continues, the manufacturer recommends a site visit and says to contact Solectria, because the inverter may need work by an authorized service provider. On string inverters, an expired fan service life is one possible cause of the external fan error alarm. The same fan alarm can also come from a blocked fan or poor contact at the fan socket connector, so check for obstructions and reseat the connector before you blame fan age. The fan error is defined as a cooling fan failure found by visual check. One manual advises watching for 5 minutes to see whether the alarm clears by itself.

<!-- review notes

Claims

observed_as

c1 drafted · lead Fan fail message

On CPS and Yaskawa PVI string inverters, the external fan error alarm (ExtFanErr) lists an expired fan service life as one possible cause. The other listed causes are a blocked fan and poor contact at the fan socket connector.

Cooling fan failure by visual check

Referenced by