active
Also known as
TempSensorErr, Prompt detection of abnormal temperature

This symptom shows up as a TempSensorErr alarm on the inverter, meaning the unit has picked up an abnormal internal temperature reading. The listed causes both point to a temperature sensor fault: either the sensor's socket connector is making poor contact, or the sensor itself is damaged. One manual notes that the sensor may read -25C. A fixed value like that, which does not change, suggests a sensor or wiring problem rather than a real cold condition. First, check the temperature value on the inverter display and see whether it makes sense. Next, reboot the inverter. On some models you do this by switching the external AC disconnect off and back on. On others you switch the internal disconnects off and then turn the inverter back on. If the alarm comes back or does not clear, suspect a loose sensor connector or a damaged sensor, and contact the manufacturer's customer service.