Solar Lattice

Symptom

DC undervoltage

ID
symptom:dc-undervoltage
IRI
https://solarlattice.org/kb/symptom/dc-undervoltage
Status
active

In analytical monitoring, the voltage at the PV array output is logged as a parameter in volts, symbol VDC. This is the channel to watch for DC undervoltage. Monitoring guidance looks at DC voltage together with module temperature, so read a low DC voltage alongside the temperature data. One inverter manual shows a curve of output derating against DC voltage, so input voltage can limit output. In the field, field instructions include checking whether DC voltage is present at the inverter input terminals and on the DC MOV board. Before you troubleshoot further, use a multimeter to confirm the DC inputs have the right polarity, because reversed inputs can damage the inverter.