Solar Lattice

Fault codes › Yaskawa Solectria › Solectria SGI 500/750XTM

Yaskawa Solectria SGI-XTM Hw Interlock

Code
Hw Interlock
Vendor severity
Informative
Page
115
ID
fc:yaskawa-solectria-sgi-500-750xtm-hwinterlock
IRI
https://solarlattice.org/kb/fc/yaskawa-solectria-sgi-500-750xtm-hwinterlock
Status
active
Also known as
Hw Interlock, hwinterlock, Yaskawa Solectria Hw Interlock
Category
Inverters
Class not stated
Production stops drafted · lead
Clears after a manual reset drafted · lead

Decoded

Reports DC undervoltage; look at PV array disconnect switch; confirm with DC voltage measurement; do: inverter restart.

What can be behind DC undervoltage

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL W001, ABB / FIMER PVS-166-175-TL W002, ABB / FIMER PVS-60-TL W001, ABB / FIMER PVS-60-TL W002, ABB / FIMER TRIO-20.0-27.6-TL W001, ABB / FIMER TRIO-20.0-27.6-TL W002, ABB / FIMER UNO-DM-3.3-5.0-PLUS W001, ABB / FIMER UNO-DM-3.3-5.0-PLUS W002, ABB / FIMER UNO-DM-6.0-PLUS W001, ABB / FIMER UNO-DM-6.0-PLUS W002
Fronius
Fronius Galvo 307, Fronius Primo 522, Fronius Primo 523, Fronius Symo 307, Fronius Symo 522, Fronius Symo 523
KACO new energy
KACO new energy blueplanet TL3 2

Claims

defined_in

c1 drafted · lead SGI 500-750XTM IOM DOCR-070506-D

reports

c2 drafted · lead DC undervoltage

Alternatively the hardware safety interlock is not satisfied.

review note: support check: partial - Description says interlock not satisfied or DC voltage too low to connect; DC undervoltage is one alternative only.

affects

c3 drafted · lead PV array disconnect switch

detected_by

c4 drafted · lead DC voltage measurement

review note: support check: partial - Corrective action says verify DC voltage, but the passage doesn't say the fault is detected by DC voltage measurement.

has_production_effect

c5 drafted · lead Trip (production stops)

Inverter cannot connect.

review note: support check: partial - 'Too low to connect' implies the inverter doesn't connect (not feeding in), but trip is not explicitly stated.

has_recovery

c6 drafted · lead Manual reset (operator restarts or acknowledges)

Check switch and DC voltage, then power-cycle; persistent case points to array sizing.