String polarity measurement

ID
method:polarity-measurement
IRI
https://solarlattice.org/kb/method/polarity-measurement
Status
active
Also known as
Polarity check, Polarity test

A string polarity measurement uses a multimeter or voltmeter to confirm that the positive and negative conductors of each PV string are wired the right way round. Connect the meter's positive lead to the string's positive cable and its negative lead to the negative cable. A negative reading on the display means the string is connected in reverse polarity. Measure each string on its own, before it is connected to other strings or the inverter. Do the check before any other tests and before switches are closed or string fuses are inserted. When a CPS inverter reports a PVxReverse fault, turn the DC switch off and open the fuse holders to isolate the strings. Then use the meter to find the reversed string and correct its wiring. An open-circuit voltage well below the expected value can also point to modules wired with the wrong polarity inside a string. The inverter does not protect against a reversed string. It is very dangerous: under strong sunlight it can blow a fuse and start a fire. If you find a reversed string on a system that was already connected, check its modules and bypass diodes for damage. Record the result for each string on the test report sheet.

<!-- review notes

Claims

produces

c1 verified · fact Negative multimeter voltage reading

With the meter's positive lead on the string's positive cable and negative lead on its negative cable, the meter's minus indicator shows the string is wired in reverse.

All digital meters have a negative ("-") indicator that indicates when a voltage is negative; in this case a string connected in reverse polarity.

verified by: review-workflowverified on: 2026-10-20

c2 verified · fact Low open-circuit voltage

A string open-circuit voltage well below the expected value can mean one or more modules in the string are connected with the wrong polarity. Shorted bypass diodes or insulation faults can cause the same reading.

verified by: review-workflowverified on: 2026-10-20