Fault codes › CPS › CPS SCA100K-T-US-480 / SCA50K-T-US-208
CPS SCA50-100K-T Protect0060
- Code
Protect0060
- Shown as
- MPPT1 CurrHigh
- Vendor severity
- Protection
- Page
- 131
- ID
fc:chint-sca-50-100k-t-protect60
- IRI
https://solarlattice.org/kb/fc/chint-sca-50-100k-t-protect60
- Status
- active
- Also known as
- Protect0060, protect60, CPS Protect0060, MPPT1 CurrHigh
- Category
- Inverters
Class
fault drafted · lead
Production
not stated
Clears
not stated
Decoded
Reports DC overcurrent; look at PV array; confirm with string polarity measurement; do: DC wiring check.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E001, ABB / FIMER PVS-60-TL E001, ABB / FIMER TRIO-20.0-27.6-TL E001, ABB / FIMER UNO-DM-3.3-5.0-PLUS E001, ABB / FIMER UNO-DM-6.0-PLUS E001
- CPS
- CPS SCA25KTL-208 PVx Over current, CPS SCA36KTL PVx Over current, CPS SCA50-100K-T Fault4030, CPS SCA50-100K-T PFault0050, CPS SCA50-100K-T Protect0360, CPS SCA50-100K-T Protect0820, CPS SCA50-100K-T Protect0850, CPS SCA50-100K-T Protect0880, CPS SCA50-60KTL PVx Over current, CPS SCH100-125KTL PV Over current, CPS SCH125KTL-AIO PV Over current
- Canadian Solar
- Canadian Solar 185-255K DC-INTF, Canadian Solar 185-255K OV-DCA-I
- Fronius
- Fronius Galvo 302, Fronius Primo 302, Fronius Symo 302
- SMA
- SMA SB-US-40 3801, SMA SB-US-41 3801, SMA SB-US-41 3802, SMA SB-US-41 3805, SMA CORE1-US 3801, SMA CORE1-US 3802, SMA CORE1-US 3803, SMA CORE1-US 3805, SMA CORE1-US 3806, SMA CORE1-US 3807, SMA CORE1-US 3808, SMA STP-TL-US 3801-3802, SMA STP-X-US 6406, SMA STP-X-US 6407, SMA SC-CP-XT 3803
- Schneider Electric
- Schneider Electric CL125 021, Schneider Electric CL125 040
- Solis
- Solis 3P-5G-US DC-INTF, Solis 3P-5G-US OV-DCA-I, Solis RHI-1P-HV DC-INTF, Solis RHI-1P-HV OV-DCA-I, Solis S6-EH1P DC-INTF, Solis S6-EH1P OV-DCA-I, Solis S6-EH2P DC-INTF, Solis S6-EH2P OV-DCA-I, Solis S6-EH2P OV-DCB-I, Solis S6-EH3P30-60K DC-INTF, Solis S6-EH3P30-60K OV-DCA-I, Solis S6-EH3P30-60K OV-DCB-I, Solis S6-EH3P75-150K DC-INTF, Solis S6-EH3P75-150K OV-DCA-I, Solis S6-EH3P75-150K OV-DCB-I, Solis S6-GC DC-INTF, Solis S6-GC OV-DCA-I, Solis S6-GC OV-DCB-I, Solis S6-GU DC-INTF, Solis S6-GU OV-DCA-I, Solis S6-GU OV-DCB-I
Claims
defined_in
c1 drafted · lead
CPS SCA100K-T-US-480 SCA50K-T-US-208 User Manual Rev 1.0
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the code prefix
reports
c3 drafted · lead
DC overcurrent
review note: support check: partial - The code is MPPT1 Current High, which implies DC overcurrent, but the passage only suggests checking PV polarity.
affects
c4 drafted · lead
PV array
review note: support check: partial - The passage mentions checking the PV input polarity, so the PV input is implied, but the PV array is not named.
detected_by
c5 drafted · lead
String polarity measurement
review note: support check: partial - The passage says to check the PV input polarity, but it does not say the fault is detected by polarity measurement.
mitigated_by
c6 drafted · lead
DC wiring check
applies_to
c7 drafted · lead
CPS SCA100K-T-US-480 / SCA50K-T-US-208
Data