Solar Lattice

Fault codes › ABB / FIMER › FIMER PVS-60-TL-US

ABB / FIMER PVS-60-TL E001

Code
E001
Shown as
Input OC
Vendor severity
Error
Page
154
ID
fc:abb-pvs-60-tl-us-e1
IRI
https://solarlattice.org/kb/fc/abb-pvs-60-tl-us-e1
Status
active
Also known as
E001, e1, ABB / FIMER E001, Input OC
Category
Inverters
Class fault drafted · lead
Production not stated
Clears not stated

Decoded

Reports DC overcurrent; look at PV array; do: string configuration correction.

What can be behind DC overcurrent

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E001, ABB / FIMER TRIO-20.0-27.6-TL E001, ABB / FIMER UNO-DM-3.3-5.0-PLUS E001, ABB / FIMER UNO-DM-6.0-PLUS E001
CPS
CPS SCA25KTL-208 PVx Over current, CPS SCA36KTL PVx Over current, CPS SCA50-100K-T Fault4030, CPS SCA50-100K-T PFault0050, CPS SCA50-100K-T Protect0360, CPS SCA50-100K-T Protect0060, CPS SCA50-100K-T Protect0820, CPS SCA50-100K-T Protect0850, CPS SCA50-100K-T Protect0880, CPS SCA50-60KTL PVx Over current, CPS SCH100-125KTL PV Over current, CPS SCH125KTL-AIO PV Over current
Canadian Solar
Canadian Solar 185-255K DC-INTF, Canadian Solar 185-255K OV-DCA-I
Fronius
Fronius Galvo 302, Fronius Primo 302, Fronius Symo 302
SMA
SMA SB-US-40 3801, SMA SB-US-41 3801, SMA SB-US-41 3802, SMA SB-US-41 3805, SMA CORE1-US 3801, SMA CORE1-US 3802, SMA CORE1-US 3803, SMA CORE1-US 3805, SMA CORE1-US 3806, SMA CORE1-US 3807, SMA CORE1-US 3808, SMA STP-TL-US 3801-3802, SMA STP-X-US 6406, SMA STP-X-US 6407, SMA SC-CP-XT 3803
Schneider Electric
Schneider Electric CL125 021, Schneider Electric CL125 040
Solis
Solis 3P-5G-US DC-INTF, Solis 3P-5G-US OV-DCA-I, Solis RHI-1P-HV DC-INTF, Solis RHI-1P-HV OV-DCA-I, Solis S6-EH1P DC-INTF, Solis S6-EH1P OV-DCA-I, Solis S6-EH2P DC-INTF, Solis S6-EH2P OV-DCA-I, Solis S6-EH2P OV-DCB-I, Solis S6-EH3P30-60K DC-INTF, Solis S6-EH3P30-60K OV-DCA-I, Solis S6-EH3P30-60K OV-DCB-I, Solis S6-EH3P75-150K DC-INTF, Solis S6-EH3P75-150K OV-DCA-I, Solis S6-EH3P75-150K OV-DCB-I, Solis S6-GC DC-INTF, Solis S6-GC OV-DCA-I, Solis S6-GC OV-DCB-I, Solis S6-GU DC-INTF, Solis S6-GU OV-DCA-I, Solis S6-GU OV-DCB-I

Same code in other families

Claims

defined_in

c1 drafted · lead FIMER PVS-60-TL-US Product Manual RevB

has_event_class

c2 drafted · lead Fault (device stops or needs intervention)

from the code prefix

reports

c3 drafted · lead DC overcurrent

affects

c4 drafted · lead PV array

mitigated_by

c5 drafted · lead String configuration correction

Check array composition and input parallel configuration first; contact service if both are correct.

applies_to

c6 drafted · lead FIMER PVS-60-TL-US string inverter

Data