Fault codes › SMA › Sunny Tripower X 13-30-US (STP xx-US-50)
SMA STP-X-US 6407
- Code
6407
- Shown as
- Self-diagnosis > Interference device
- Page
- 91
- ID
fc:sma-stp-x-us-50-6407
- IRI
https://solarlattice.org/kb/fc/sma-stp-x-us-50-6407
- Status
- active
- Also known as
- 6407, SMA 6407, Self-diagnosis > Interference device
- Category
- Inverters
Class
not stated
Production
not stated
Clears
not stated
Decoded
Reports DC overcurrent; look at PV array; do: string configuration correction, inverter replacement.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
- STPxx-US-50-BE-en-14 — SMA · page 91 drafted · lead
sec=11.1.32 h=8f19152722c3
sec=h525 h=75f49e9e17fb
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E001, ABB / FIMER PVS-60-TL E001, ABB / FIMER TRIO-20.0-27.6-TL E001, ABB / FIMER UNO-DM-3.3-5.0-PLUS E001, ABB / FIMER UNO-DM-6.0-PLUS E001
- CPS
- CPS SCA25KTL-208 PVx Over current, CPS SCA36KTL PVx Over current, CPS SCA50-100K-T Fault4030, CPS SCA50-100K-T PFault0050, CPS SCA50-100K-T Protect0360, CPS SCA50-100K-T Protect0060, CPS SCA50-100K-T Protect0820, CPS SCA50-100K-T Protect0850, CPS SCA50-100K-T Protect0880, CPS SCA50-60KTL PVx Over current, CPS SCH100-125KTL PV Over current, CPS SCH125KTL-AIO PV Over current
- Canadian Solar
- Canadian Solar 185-255K DC-INTF, Canadian Solar 185-255K OV-DCA-I
- Fronius
- Fronius Galvo 302, Fronius Primo 302, Fronius Symo 302
- SMA
- SMA SB-US-40 3801, SMA SB-US-41 3801, SMA SB-US-41 3802, SMA SB-US-41 3805, SMA CORE1-US 3801, SMA CORE1-US 3802, SMA CORE1-US 3803, SMA CORE1-US 3805, SMA CORE1-US 3806, SMA CORE1-US 3807, SMA CORE1-US 3808, SMA STP-TL-US 3801-3802, SMA STP-X-US 6406, SMA SC-CP-XT 3803
- Schneider Electric
- Schneider Electric CL125 021, Schneider Electric CL125 040
- Solis
- Solis 3P-5G-US DC-INTF, Solis 3P-5G-US OV-DCA-I, Solis RHI-1P-HV DC-INTF, Solis RHI-1P-HV OV-DCA-I, Solis S6-EH1P DC-INTF, Solis S6-EH1P OV-DCA-I, Solis S6-EH2P DC-INTF, Solis S6-EH2P OV-DCA-I, Solis S6-EH2P OV-DCB-I, Solis S6-EH3P30-60K DC-INTF, Solis S6-EH3P30-60K OV-DCA-I, Solis S6-EH3P30-60K OV-DCB-I, Solis S6-EH3P75-150K DC-INTF, Solis S6-EH3P75-150K OV-DCA-I, Solis S6-EH3P75-150K OV-DCB-I, Solis S6-GC DC-INTF, Solis S6-GC OV-DCA-I, Solis S6-GC OV-DCB-I, Solis S6-GU DC-INTF, Solis S6-GU OV-DCA-I, Solis S6-GU OV-DCB-I
Claims
defined_in
c1 drafted · lead
STPxx-US-50-BE-en-14
reports
c2 drafted · lead
DC overcurrent
The DC input hardware overcurrent threshold was exceeded.
affects
c3 drafted · lead
PV array
mitigated_by
c4 drafted · lead
String configuration correction
c5 drafted · lead
Inverter replacement
Only if the message is permanently present.
applies_to
c6 drafted · lead
Sunny Tripower X US-50
Data