Fault codes › CPS › CPS SCA25KTL-DO/US-208
CPS SCA25KTL-208 PVx Over current
- Code
PVx Over current
- Shown as
- PVx Over current x=1,2,3
- Vendor severity
- Protection
- Page
- 127
- ID
fc:chint-sca-25ktl-208-pvxovercurrent
- IRI
https://solarlattice.org/kb/fc/chint-sca-25ktl-208-pvxovercurrent
- Status
- active
- Also known as
- PVx Over current, pvxovercurrent, CPS PVx Over current, PVx Over current x=1,2,3
- Category
- Inverters
Class
fault drafted · lead
Production
stops drafted · lead
Decoded
Reports DC overcurrent; confirm with string current measurement; do: inverter restart, inverter replacement.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E001, ABB / FIMER PVS-60-TL E001, ABB / FIMER TRIO-20.0-27.6-TL E001, ABB / FIMER UNO-DM-3.3-5.0-PLUS E001, ABB / FIMER UNO-DM-6.0-PLUS E001
- CPS
- CPS SCA36KTL PVx Over current, CPS SCA50-100K-T Fault4030, CPS SCA50-100K-T PFault0050, CPS SCA50-100K-T Protect0360, CPS SCA50-100K-T Protect0060, CPS SCA50-100K-T Protect0820, CPS SCA50-100K-T Protect0850, CPS SCA50-100K-T Protect0880, CPS SCA50-60KTL PVx Over current, CPS SCH100-125KTL PV Over current, CPS SCH125KTL-AIO PV Over current
- Canadian Solar
- Canadian Solar 185-255K DC-INTF, Canadian Solar 185-255K OV-DCA-I
- Fronius
- Fronius Galvo 302, Fronius Primo 302, Fronius Symo 302
- SMA
- SMA SB-US-40 3801, SMA SB-US-41 3801, SMA SB-US-41 3802, SMA SB-US-41 3805, SMA CORE1-US 3801, SMA CORE1-US 3802, SMA CORE1-US 3803, SMA CORE1-US 3805, SMA CORE1-US 3806, SMA CORE1-US 3807, SMA CORE1-US 3808, SMA STP-TL-US 3801-3802, SMA STP-X-US 6406, SMA STP-X-US 6407, SMA SC-CP-XT 3803
- Schneider Electric
- Schneider Electric CL125 021, Schneider Electric CL125 040
- Solis
- Solis 3P-5G-US DC-INTF, Solis 3P-5G-US OV-DCA-I, Solis RHI-1P-HV DC-INTF, Solis RHI-1P-HV OV-DCA-I, Solis S6-EH1P DC-INTF, Solis S6-EH1P OV-DCA-I, Solis S6-EH2P DC-INTF, Solis S6-EH2P OV-DCA-I, Solis S6-EH2P OV-DCB-I, Solis S6-EH3P30-60K DC-INTF, Solis S6-EH3P30-60K OV-DCA-I, Solis S6-EH3P30-60K OV-DCB-I, Solis S6-EH3P75-150K DC-INTF, Solis S6-EH3P75-150K OV-DCA-I, Solis S6-EH3P75-150K OV-DCB-I, Solis S6-GC DC-INTF, Solis S6-GC OV-DCA-I, Solis S6-GC OV-DCB-I, Solis S6-GU DC-INTF, Solis S6-GU OV-DCA-I, Solis S6-GU OV-DCB-I
Same code in other families
Claims
defined_in
c1 drafted · lead
CPS SCA25KTL-DO-US-208 User Manual Rev 1.2
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the Type column
reports
c3 drafted · lead
DC overcurrent
detected_by
c4 drafted · lead
String current measurement
review note: support check: partial - The passage says to check PV input current but does not describe string current measurement as the detection method.
mitigated_by
c5 drafted · lead
Inverter restart
c6 drafted · lead
Inverter replacement
has_production_effect
c7 drafted · lead
Trip (production stops)
review note: support check: partial - The passage gives no explicit stop or trip behaviour.
has_recovery
c8 drafted · lead
Manual reset (operator restarts or acknowledges)
Check input current, then power cycle; replace inverter if fault persists.
applies_to
c9 drafted · lead
CPS SCA25KTL-DO/US-208
Data