Fault codes › SMA › Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)
SMA STP-TL-US 3801-3802
- Code
3801-3802
- Page
- 49
- ID
fc:sma-stp-tl-us-3801-3802
- IRI
https://solarlattice.org/kb/fc/sma-stp-tl-us-3801-3802
- Status
- active
- Also known as
- 3801-3802, SMA 3801-3802
- Category
- Inverters
Class
not stated
Production
stops drafted · lead
Decoded
Reports DC overcurrent; look at PV array; do: string configuration correction.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E001, ABB / FIMER PVS-60-TL E001, ABB / FIMER TRIO-20.0-27.6-TL E001, ABB / FIMER UNO-DM-3.3-5.0-PLUS E001, ABB / FIMER UNO-DM-6.0-PLUS E001
- CPS
- CPS SCA25KTL-208 PVx Over current, CPS SCA36KTL PVx Over current, CPS SCA50-100K-T Fault4030, CPS SCA50-100K-T PFault0050, CPS SCA50-100K-T Protect0360, CPS SCA50-100K-T Protect0060, CPS SCA50-100K-T Protect0820, CPS SCA50-100K-T Protect0850, CPS SCA50-100K-T Protect0880, CPS SCA50-60KTL PVx Over current, CPS SCH100-125KTL PV Over current, CPS SCH125KTL-AIO PV Over current
- Canadian Solar
- Canadian Solar 185-255K DC-INTF, Canadian Solar 185-255K OV-DCA-I
- Fronius
- Fronius Galvo 302, Fronius Primo 302, Fronius Symo 302
- SMA
- SMA SB-US-40 3801, SMA SB-US-41 3801, SMA SB-US-41 3802, SMA SB-US-41 3805, SMA CORE1-US 3801, SMA CORE1-US 3802, SMA CORE1-US 3803, SMA CORE1-US 3805, SMA CORE1-US 3806, SMA CORE1-US 3807, SMA CORE1-US 3808, SMA STP-X-US 6406, SMA STP-X-US 6407, SMA SC-CP-XT 3803
- Schneider Electric
- Schneider Electric CL125 021, Schneider Electric CL125 040
- Solis
- Solis 3P-5G-US DC-INTF, Solis 3P-5G-US OV-DCA-I, Solis RHI-1P-HV DC-INTF, Solis RHI-1P-HV OV-DCA-I, Solis S6-EH1P DC-INTF, Solis S6-EH1P OV-DCA-I, Solis S6-EH2P DC-INTF, Solis S6-EH2P OV-DCA-I, Solis S6-EH2P OV-DCB-I, Solis S6-EH3P30-60K DC-INTF, Solis S6-EH3P30-60K OV-DCA-I, Solis S6-EH3P30-60K OV-DCB-I, Solis S6-EH3P75-150K DC-INTF, Solis S6-EH3P75-150K OV-DCA-I, Solis S6-EH3P75-150K OV-DCB-I, Solis S6-GC DC-INTF, Solis S6-GC OV-DCA-I, Solis S6-GC OV-DCB-I, Solis S6-GU DC-INTF, Solis S6-GU OV-DCA-I, Solis S6-GU OV-DCB-I
Claims
defined_in
c1 drafted · lead
STPTL-US-10-IA-xx-22
reports
c2 drafted · lead
DC overcurrent
affects
c3 drafted · lead
PV array
mitigated_by
c4 drafted · lead
String configuration correction
Only if the message appears frequently.
has_production_effect
c5 drafted · lead
Trip (production stops)
review note: support check: partial - Feed-in is briefly interrupted, which is a trip, though the effect is only brief.
has_recovery
c6 drafted · lead
Auto-reset (clears by itself)
Feed-in is interrupted only briefly.
review note: support check: partial - The brief interruption implies resumption, but auto-reset is not explicitly stated.
applies_to
c7 drafted · lead
Sunny Tripower TL-US
Data