Solar Lattice

Fault codes › SMA › Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)

SMA STP-TL-US 3801-3802

Code
3801-3802
Page
49
ID
fc:sma-stp-tl-us-3801-3802
IRI
https://solarlattice.org/kb/fc/sma-stp-tl-us-3801-3802
Status
active
Also known as
3801-3802, SMA 3801-3802
Category
Inverters
Class not stated
Production stops drafted · lead
Clears by itself drafted · lead

Decoded

Reports DC overcurrent; look at PV array; do: string configuration correction.

What can be behind DC overcurrent

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E001, ABB / FIMER PVS-60-TL E001, ABB / FIMER TRIO-20.0-27.6-TL E001, ABB / FIMER UNO-DM-3.3-5.0-PLUS E001, ABB / FIMER UNO-DM-6.0-PLUS E001
CPS
CPS SCA25KTL-208 PVx Over current, CPS SCA36KTL PVx Over current, CPS SCA50-100K-T Fault4030, CPS SCA50-100K-T PFault0050, CPS SCA50-100K-T Protect0360, CPS SCA50-100K-T Protect0060, CPS SCA50-100K-T Protect0820, CPS SCA50-100K-T Protect0850, CPS SCA50-100K-T Protect0880, CPS SCA50-60KTL PVx Over current, CPS SCH100-125KTL PV Over current, CPS SCH125KTL-AIO PV Over current
Canadian Solar
Canadian Solar 185-255K DC-INTF, Canadian Solar 185-255K OV-DCA-I
Fronius
Fronius Galvo 302, Fronius Primo 302, Fronius Symo 302
SMA
SMA SB-US-40 3801, SMA SB-US-41 3801, SMA SB-US-41 3802, SMA SB-US-41 3805, SMA CORE1-US 3801, SMA CORE1-US 3802, SMA CORE1-US 3803, SMA CORE1-US 3805, SMA CORE1-US 3806, SMA CORE1-US 3807, SMA CORE1-US 3808, SMA STP-X-US 6406, SMA STP-X-US 6407, SMA SC-CP-XT 3803
Schneider Electric
Schneider Electric CL125 021, Schneider Electric CL125 040
Solis
Solis 3P-5G-US DC-INTF, Solis 3P-5G-US OV-DCA-I, Solis RHI-1P-HV DC-INTF, Solis RHI-1P-HV OV-DCA-I, Solis S6-EH1P DC-INTF, Solis S6-EH1P OV-DCA-I, Solis S6-EH2P DC-INTF, Solis S6-EH2P OV-DCA-I, Solis S6-EH2P OV-DCB-I, Solis S6-EH3P30-60K DC-INTF, Solis S6-EH3P30-60K OV-DCA-I, Solis S6-EH3P30-60K OV-DCB-I, Solis S6-EH3P75-150K DC-INTF, Solis S6-EH3P75-150K OV-DCA-I, Solis S6-EH3P75-150K OV-DCB-I, Solis S6-GC DC-INTF, Solis S6-GC OV-DCA-I, Solis S6-GC OV-DCB-I, Solis S6-GU DC-INTF, Solis S6-GU OV-DCA-I, Solis S6-GU OV-DCB-I

Claims

defined_in

c1 drafted · lead STPTL-US-10-IA-xx-22

reports

c2 drafted · lead DC overcurrent

affects

c3 drafted · lead PV array

mitigated_by

c4 drafted · lead String configuration correction

Only if the message appears frequently.

has_production_effect

c5 drafted · lead Trip (production stops)

review note: support check: partial - Feed-in is briefly interrupted, which is a trip, though the effect is only brief.

has_recovery

c6 drafted · lead Auto-reset (clears by itself)

Feed-in is interrupted only briefly.

review note: support check: partial - The brief interruption implies resumption, but auto-reset is not explicitly stated.

applies_to

c7 drafted · lead Sunny Tripower TL-US

Data