Solar Lattice

Fault codes › CPS › CPS SCA100K-T-US-480 / SCA50K-T-US-208

CPS SCA50-100K-T Fault1000-1070

Code
Fault1000-1070
Shown as
PV1…PV16 SwitchConnec tError
Vendor severity
Fault
Page
144
ID
fc:chint-sca-50-100k-t-fault1000-1070
IRI
https://solarlattice.org/kb/fc/chint-sca-50-100k-t-fault1000-1070
Status
active
Also known as
Fault1000-1070, fault1000-1070, CPS Fault1000-1070, PV1…PV16 SwitchConnec tError
Category
Inverters
Class fault drafted · lead
Production not stated
Clears after a manual reset drafted · lead

Decoded

Reports abnormal PV input; look at PV array disconnect switch; confirm with string polarity measurement; do: DC wiring check.

What can be behind Abnormal PV input

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

CPS
CPS SCA50-100K-T Fault0000-0150, CPS SCA50-100K-T Fault5000, CPS SCA50-100K-T Protect0380
Huawei
Huawei SUN2000-45KTL-US-HV-D0 413
SMA
SMA SBSE-US-50 6801, SMA SBSE-US-50 6901, SMA STP-TL-US 6801-6802, SMA STP-TL-US 6901-6902, SMA SI-US W854, SMA SI-US W864, SMA SI-US W874, SMA SI-US W884
Sungrow
Sungrow SG-CX-US 220-227, Sungrow SG-CX-US 548-563, Sungrow SG-CX-US 580-587, Sungrow SG-CX-US 078-081, Sungrow SG200HX 548-563, Sungrow SG200HX 580-595, Sungrow SG250HX 548-563, Sungrow SG250HX 580-595, Sungrow SG350HX 548-563, Sungrow SG350HX 580-595

Claims

defined_in

c1 drafted · lead CPS SCA100K-T-US-480 SCA50K-T-US-208 User Manual Rev 1.0

has_event_class

c2 drafted · lead Fault (device stops or needs intervention)

from the code prefix

reports

c3 drafted · lead Abnormal PV input

affects

c4 drafted · lead PV array disconnect switch

detected_by

c5 drafted · lead String polarity measurement

Used when alarm does not clear by itself.

mitigated_by

c6 drafted · lead DC wiring check

Correct reversed string connection if alarm persists; then service.

has_recovery

c7 drafted · lead Manual reset (operator restarts or acknowledges)

Even after self-clearing, DC switches are cycled and inverter restarted; wiring check then service if persisting.

applies_to

c8 drafted · lead CPS SCA100K-T-US-480 / SCA50K-T-US-208

Data