Fan replacement
Fan replacement means swapping out a broken inverter cooling fan. It addresses fan failure, which shows up as the ExtFanErr alarm on CPS SCA inverters or a Fan Fail warning on other inverters. The fan matters because a fan that does not work leaves the inverter poorly cooled. Fan failure is one of the listed causes of inverter overheating and temperature derating. Before replacing anything, wait 5 minutes to see if the alarm clears by itself. Next, check the blades for foreign objects. Then switch the external AC disconnect off and back on to reboot the system. On CPS units, if ExtFanErr appears while output is above 50% of rated output and the fan is still spinning, replace the inverter instead, because the problem is in the sensing circuit. If the fan is not spinning, remove the 6 bolts holding the two external fans. Open the white snap-on connector and measure the voltage across the red and black wire pins. Below 6 VDC, replace the inverter. Above 6 V, replace the fan. Before working on the fan, the Solis procedure switches the grid off from the LCD, disconnects AC, turns the DC switch off and waits at least 15 minutes. Then the fan assembly is pulled out, cleaned or replaced, reconnected and the inverter restarted. Fan replacement does not fix every fan alarm. On CPS units, an internal fan error (IntFanErr) calls for replacing the whole inverter, and you should contact post-sales service if the fault remains.
<!-- review notes
- sentence 7: support check: partial - IntFanErr says replace the inverter, but the 'contact post-sales service if fault remains' is only for ExtFanErr alarm, not IntFanErr. -->
Referenced by
- Inverter cooling
related_toc9 - CPS SCA36KTL ExtFanErr
mitigated_byc7 - CPS SCA50-60KTL ExtFanErr
mitigated_byc7 - Schneider Electric CL125 037
mitigated_byc6 - Schneider Electric CL125 070
mitigated_byc6 - SMA STP-TL-US 7508
mitigated_byc6 - Sungrow SG-CX-US 036
mitigated_byc8 - Sungrow SG-CX-US 037
mitigated_byc10 - Sungrow SG-CX-US 070
mitigated_byc8 - Sungrow SG200HX 036
mitigated_byc7 - Sungrow SG200HX 037
mitigated_byc9 - Sungrow SG250HX 36
mitigated_byc6 - Sungrow SG250HX 37
mitigated_byc7 - Sungrow SG350HX 036
mitigated_byc7 - Sungrow SG350HX 037
mitigated_byc9 - Yaskawa Solectria XGI-1500-1MW CRIT-6
mitigated_byc7 - Yaskawa Solectria XGI-1500-1MW INFO-1
mitigated_byc6 - Yaskawa Solectria XGI-1500 CRIT-6
mitigated_byc9 - Yaskawa Solectria XGI-1500-DCG CRIT-6
mitigated_byc7 - Yaskawa Solectria XGI-1500-DCG INFO-1
mitigated_byc6 - Yaskawa Solectria XGI-1500 INFO-1
mitigated_byc8 - Fan failure
mitigated_byc14