Solar Lattice

Fault codes › ABB / FIMER › UNO-DM-6.0-TL-PLUS-US

ABB / FIMER UNO-DM-6.0-PLUS W010

Code
W010
Shown as
Fan Fail
Vendor severity
Warning
Page
122
ID
fc:abb-uno-dm-6-0-plus-us-w10
IRI
https://solarlattice.org/kb/fc/abb-uno-dm-6-0-plus-us-w10
Status
active
Also known as
W010, w10, ABB / FIMER W010, Fan Fail
Category
Inverters
Class warning drafted · lead
Production not stated
Clears needs service drafted · lead

Decoded

Reports fan fault alarm; may indicate fan failure; look at cooling fan; do: contact manufacturer service.

What can be behind Fan fault alarm

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-60-TL W010, ABB / FIMER TRIO-20.0-27.6-TL W010, ABB / FIMER UNO-DM-3.3-5.0-PLUS W010
CPS
CPS SCA25KTL-208 ExtFanErr, CPS SCA25KTL-480 ExtFanErr, CPS SCA25KTL-480 IntFanErr, CPS SCA50-100K-T Warn0000, CPS SCA50-100K-T Warn0010, CPS SCH100-125KTL ExtFanErr, CPS SCH100-125KTL IntFanErr, CPS SCH125KTL-AIO ExtFanErr, CPS SCH200-250K-T ExtFanErr, CPS SCH200-250K-T IntFanErr, CPS SCH275KTL ExtFanErr, CPS SCH275KTL IntFanErr, CPS SCH350KTL ExtFanErr, CPS SCH350KTL IntFanErr, CPS SCH350KTL Warn0080
Canadian Solar
Canadian Solar 23-28KTL-CT ExtFanErr
Fronius
Fronius Symo 326, Fronius Symo 327
KACO new energy
KACO new energy blueplanet TL3 187, KACO new energy blueplanet TL3 70, KACO new energy blueplanet TL3 71, KACO new energy blueplanet TL3 72
SMA
SMA STP-TL-US 7508, SMA SC-CP-XT 7507
Schneider Electric
Schneider Electric CL125 070
Solis
Solis S6-EH2P Fan Alarm, Solis S6-EH3P30-60K Fan Alarm, Solis S6-EH3P75-150K Fan Alarm
Sungrow
Sungrow SG-CX-US 070
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL ExtFanErr, Yaskawa Solectria PVI-14-20TL IntFanErr, Yaskawa Solectria PVI-25TL-R IntFanErr, Yaskawa Solectria PVI-TL ExtFanErr, Yaskawa Solectria PVI-TL IntFanErr

Same code in other families

Claims

defined_in

c1 drafted · lead FIMER UNO-DM-6.0-TL-PLUS-US-Q Product Manual RevB

c2 drafted · lead UNO-DM-6.0-TL-PLUS-US Product Manual RevA

has_event_class

c3 drafted · lead Warning (device continues, a condition is flagged)

from the code prefix

reports

c4 drafted · lead Fan fault alarm

indicates

c5 drafted · lead Fan failure

affects

c6 drafted · lead Cooling fan

mitigated_by

c7 drafted · lead Contact manufacturer service

has_recovery

c8 drafted · lead Service required

Internal fault that cannot be checked externally; call service if the alarm keeps repeating.

review note: support check: partial - Internal error that can't be checked externally and contact assistance if repeating are stated, though 'clears by service required' is…

applies_to

c9 drafted · lead UNO-DM-6.0-TL-PLUS-US string inverter

Data