c1 drafted · lead FIMER UNO-DM-6.0-TL-PLUS-US-Q Product Manual RevB
- FIMER UNO-DM-6.0-TL-PLUS-US-Q Product Manual RevB
tbl=35.r7h=bd1f9d50b28e
Fault codes › ABB / FIMER › UNO-DM-6.0-TL-PLUS-US
Reports surge protector alarm; may indicate surge protector exhausted; look at surge protection device; confirm with visual inspection; do: SPD replacement.
Failure modes that present as the reported condition, and the tests that tell them apart.
tbl=35.r7 h=bd1f9d50b28etbl=46.r7 h=a364c09b556eThe manufacturer's own cause and corrective text is not reproduced here.
defined_inc1 drafted · lead FIMER UNO-DM-6.0-TL-PLUS-US-Q Product Manual RevB
tbl=35.r7 h=bd1f9d50b28ec2 drafted · lead UNO-DM-6.0-TL-PLUS-US Product Manual RevA
tbl=46.r7 h=a364c09b556ehas_event_classc3 drafted · lead Warning (device continues, a condition is flagged)
from the code prefix
tbl=35.r7 h=bd1f9d50b28etbl=46.r7 h=a364c09b556ereportsc4 drafted · lead Surge protector alarm
Only on models with monitored SPD
tbl=51.r5 h=19da0db7d78etbl=44.r6 h=12de0561a1fctbl=37.r7 h=bd1f9d50b28etbl=35.r7 h=bd1f9d50b28etbl=51.r7 h=a364c09b556etbl=46.r7 h=a364c09b556etbl=36.r7 h=17319027a480indicatesc5 drafted · lead Surge protector exhausted
tbl=51.r5 h=19da0db7d78etbl=44.r6 h=12de0561a1fctbl=37.r7 h=bd1f9d50b28etbl=35.r7 h=bd1f9d50b28etbl=51.r7 h=a364c09b556etbl=46.r7 h=a364c09b556etbl=36.r7 h=17319027a480affectsc6 drafted · lead Surge protection device
AC-side surge arresters
tbl=51.r5 h=19da0db7d78etbl=44.r6 h=12de0561a1fctbl=37.r7 h=bd1f9d50b28etbl=35.r7 h=bd1f9d50b28etbl=51.r7 h=a364c09b556etbl=46.r7 h=a364c09b556etbl=36.r7 h=17319027a480detected_byc7 drafted · lead Visual inspection
Check each arrester's inspection window; red means damaged
tbl=51.r5 h=19da0db7d78etbl=44.r6 h=12de0561a1fctbl=37.r7 h=bd1f9d50b28etbl=35.r7 h=bd1f9d50b28etbl=51.r7 h=a364c09b556etbl=46.r7 h=a364c09b556etbl=36.r7 h=17319027a480mitigated_byc8 drafted · lead SPD replacement
tbl=51.r5 h=19da0db7d78etbl=44.r6 h=12de0561a1fctbl=37.r7 h=bd1f9d50b28etbl=35.r7 h=bd1f9d50b28etbl=51.r7 h=a364c09b556etbl=46.r7 h=a364c09b556etbl=36.r7 h=17319027a480has_recoveryc9 drafted · lead Service required
Replace damaged cartridge; if alarm persists with all windows green, contact support
tbl=51.r5 h=19da0db7d78etbl=44.r6 h=12de0561a1fctbl=37.r7 h=bd1f9d50b28etbl=35.r7 h=bd1f9d50b28etbl=51.r7 h=a364c09b556etbl=46.r7 h=a364c09b556etbl=36.r7 h=17319027a480review note: support check: partial - Replacement and contacting assistance if persisting are stated, but service-required clearing is only implied for the persistent case.
applies_toc10 drafted · lead UNO-DM-6.0-TL-PLUS-US string inverter
tbl=35.r7 h=bd1f9d50b28etbl=46.r7 h=a364c09b556e