c1 drafted · lead CPS SCA100K-T-US-480 SCA50K-T-US-208 User Manual Rev 1.0
- CPS SCA100K-T-US-480 SCA50K-T-US-208 User Manual Rev 1.0
tbl=46.r1h=f41c5a6846da
Fault codes › CPS › CPS SCA100K-T-US-480 / SCA50K-T-US-208
Reports internal communication failure; do: communication cable check.
Failure modes that present as the reported condition, and the tests that tell them apart.
tbl=46.r1 h=f41c5a6846daThe manufacturer's own cause and corrective text is not reproduced here.
defined_inc1 drafted · lead CPS SCA100K-T-US-480 SCA50K-T-US-208 User Manual Rev 1.0
tbl=46.r1 h=f41c5a6846dahas_event_classc2 drafted · lead Warning (device continues, a condition is flagged)
from the code prefix
tbl=46.r1 h=f41c5a6846dareportsc3 drafted · lead Internal communication failure
tbl=46.r1 h=f41c5a6846damitigated_byc4 drafted · lead Communication cable check
tbl=46.r1 h=f41c5a6846dareview note: support check: partial - The cause is poor contact of the internal communication wire terminals, but the solutions don't list a communication cable check.
has_recoveryc5 drafted · lead Auto-reset (clears by itself)
Observe first; if it persists, restart, then contact service.
tbl=46.r1 h=f41c5a6846daapplies_toc6 drafted · lead CPS SCA100K-T-US-480 / SCA50K-T-US-208
tbl=46.r1 h=f41c5a6846da