Fault codes › SMA › Sunny Tripower CORE1-US (STP 33/50/62-US-41)
SMA CORE1-US 7622
- Code
7622
- Page
- 52
- ID
fc:sma-stp-core1-us-7622
- IRI
https://solarlattice.org/kb/fc/sma-stp-core1-us-7622
- Status
- active
- Also known as
- 7622, SMA 7622
- Category
- Inverters
Class
fault verified · fact
Production
stops verified · fact
Clears
not stated
Decoded
Reports internal communication failure; look at I/O module.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E003, ABB / FIMER PVS-166-175-TL E005, ABB / FIMER PVS-166-175-TL E054, ABB / FIMER PVS-166-175-TL E074, ABB / FIMER PVS-60-TL E003, ABB / FIMER PVS-60-TL E005, ABB / FIMER PVS-60-TL E054, ABB / FIMER PVS-60-TL E074, ABB / FIMER TRIO-20.0-27.6-TL E003, ABB / FIMER TRIO-20.0-27.6-TL E005, ABB / FIMER UNO-DM-3.3-5.0-PLUS E003, ABB / FIMER UNO-DM-3.3-5.0-PLUS E005, ABB / FIMER UNO-DM-3.3-5.0-PLUS E054, ABB / FIMER UNO-DM-6.0-PLUS E003, ABB / FIMER UNO-DM-6.0-PLUS E005, ABB / FIMER UNO-DM-6.0-PLUS E054
- CPS
- CPS SCA25KTL-208 CommErr, CPS SCA25KTL-480 CommErr, CPS SCA50-100K-T Fault6050, CPS SCA50-100K-T Fault6100, CPS SCA50-100K-T Protect1070, CPS SCA50-100K-T Protect0770, CPS SCA50-100K-T Warn0020, CPS SCH100-125KTL CommErr, CPS SCH125KTL-AIO CommErr, CPS SCH200-250K-T CommErr, CPS SCH275KTL CommErr, CPS SCH350KTL CommErr
- Canadian Solar
- Canadian Solar 185-255K DSP-B-FAULT, Canadian Solar 23-28KTL-CT CommErr
- Fronius
- Fronius Galvo 401, Fronius Galvo 416, Fronius Galvo 425, Fronius Galvo 452, Fronius Galvo 752, Fronius Primo 401, Fronius Primo 416, Fronius Primo 425, Fronius Primo 452, Fronius Primo 485, Fronius Primo 515, Fronius Primo 516, Fronius Primo 752, Fronius Symo 401, Fronius Symo 416, Fronius Symo 425, Fronius Symo 452, Fronius Symo 485, Fronius Symo 515, Fronius Symo 516, Fronius Symo 519, Fronius Symo 601, Fronius Symo 752
- Huawei
- Huawei SUN2000-25-30KTL-US 322, Huawei SUN2000-45KTL-US-HV-D0 322
- KACO new energy
- KACO new energy blueplanet TL3 34
- SMA
- SMA SB-US-40 6701-6702, SMA SB-US-41 6701, SMA SB-US-41 6702, SMA PEAK3-US 6701, SMA CORE1-US 6701, SMA CORE1-US 6702, SMA STP-TL-US 6701-6702, SMA SC-CP-XT 6119, SMA SC-CP-XT 7600, SMA SC-CP-XT 7602, SMA SC-CP-XT 7605, SMA SI-US F739, SMA SI-US F743, SMA SI-US W740, SMA SI-US W741, SMA SI-US W742, SMA SI-US W744, SMA SI-US W745, SMA SI-US W746
- Schneider Electric
- Schneider Electric CL125 059, Schneider Electric CL125 074
- Solis
- Solis 3P-5G-US DSP-B-Fault, Solis RHI-1P-HV DSP-B-Fault, Solis S6-EH1P DSP-B-Fault, Solis S6-EH2P DSP-B-Fault, Solis S6-EH3P30-60K DSP-B-Fault, Solis S6-EH3P75-150K DSP-B-Fault, Solis S6-GC DSP-B-Fault, Solis S6-GU DSP-B-Fault
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL SPICommErr, Yaskawa Solectria PVI-25TL-R CommErr, Yaskawa Solectria PVI-TL SPICommErr, Yaskawa Solectria XGI-1500-1MW CRIT-2, Yaskawa Solectria XGI-1500-1MW CRIT-3, Yaskawa Solectria XGI-1500 CRIT-2, Yaskawa Solectria XGI-1500 CRIT-3, Yaskawa Solectria XGI-1500-DCG CRIT-2, Yaskawa Solectria XGI-1500-DCG CRIT-3
Claims
defined_in
c1 drafted · lead
STP33-62-US-41-BA-en-13
c2 drafted · lead
STP33-62-US-41 ops manual
c3 drafted · lead
STP33-62-US-41-BA-en-14
reports
c4 drafted · lead
Internal communication failure
affects
c5 verified · fact
I/O module
verified by: review-workflowverified on: 2026-10-20
has_production_effect
c6 verified · fact
Trip (production stops)
Inverter disconnects from the grid for safety.
verified by: review-workflowverified on: 2026-10-20
has_event_class
c7 verified · fact
Fault (device stops or needs intervention)
verified by: review-workflowverified on: 2026-10-20
applies_to
c8 drafted · lead
Sunny Tripower CORE1-US