On Fronius Symo UL inverters this shows as status code 314. Grid feed-in stops briefly, then the inverter goes back to its startup phase.
- fronius-symo-ul-emanual-status-codes
tbl=14.r13h=c13abd994ee5
On a Fronius Symo inverter this symptom shows as status code 314, which reports that current sensor calibration timed out. The inverter stops feeding the grid for a short time and then returns to its startup phase, so monitoring data show a brief drop in AC power followed by a restart. The same manual lists a separate code, 315, for an AC current sensor fault. If that code also appears, the problem is more likely the sensor itself than a single calibration timeout. Other inverter makers report similar problems as a failed current sensor offset calibration, or as a current sensor that is not connected, not available or defective. When a calibration error keeps coming back, the manufacturer's service team has to find the cause, so contact service instead of trying to repair the sensor in the field.