Solar Lattice

Symptom

Arc detection disabled

ID
symptom:arc-detection-disabled
IRI
https://solarlattice.org/kb/symptom/arc-detection-disabled
Status
active
Also known as
Arc Detector switched off

On Fronius Galvo, Primo and Symo inverters, a disabled arc detector shows up as status code 566 on the inverter display. The usual reason is that the internal Arc Detector was turned off on purpose, for example because arcs are monitored by external equipment. The code comes back every day until the Arc Detector is switched on again. The manufacturer says this is not an error, and you can confirm the code by pressing the Enter key. To check the current state of arc detection and interruption, open Arc.det. Status in the INFO menu. The Arc Detection setup item has a status view and a self-test start, so you can confirm the detector works after you turn it back on. On some other inverters, arc protection is turned on or off with a parameter that is enabled by default, so check that setting first.

<!-- review notes

Claims

observed_as

c1 drafted · lead Inverter fault code display

On Fronius Galvo, Primo and Symo inverters, status code 566 shows when the Arc Detector has been switched off, for example because arc monitoring is done externally. The code comes back every day until the Arc Detector is turned back on. The manuals say it is not an error and is cleared by pressing Enter.

c2 drafted · lead Arc detector status reading

The Arc.det. Status item in the Fronius INFO menu shows the current state of arc detection and interruption.

review note: support check: partial - Passages say Arc.det. Status shows the current arc detection/interruption status, but don't mention the Fronius INFO menu or that it reflects disabled state.; review: partial - The passages say Arc.det. Status shows the current status of arc detection/interruption, but they never mention a Fronius INFO menu.