Solar Lattice

Fault codes › Fronius › Fronius Primo 208-240 (3.8-1 to 15.0-1)

Fronius Primo 445

Code
445
Shown as
Limit value settings not permissible
Vendor severity
Class 4
ID
fc:fronius-primo-445
IRI
https://solarlattice.org/kb/fc/fronius-primo-445
Status
active
Also known as
445, Fronius 445, Limit value settings not permissible
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears not stated

Decoded

Reports hardware component incompatibility, configuration error; do: firmware update.

What can be behind Hardware component incompatibility

Failure modes that present as the reported condition, and the tests that tell them apart.

What can be behind Configuration error

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E055, ABB / FIMER PVS-166-175-TL E077, ABB / FIMER PVS-60-TL E013, ABB / FIMER PVS-60-TL E055, ABB / FIMER PVS-60-TL E077, ABB / FIMER TRIO-20.0-27.6-TL E013, ABB / FIMER TRIO-20.0-27.6-TL W009, ABB / FIMER UNO-DM-3.3-5.0-PLUS E013, ABB / FIMER UNO-DM-3.3-5.0-PLUS E055, ABB / FIMER UNO-DM-3.3-5.0-PLUS E077, ABB / FIMER UNO-DM-6.0-PLUS E013, ABB / FIMER UNO-DM-6.0-PLUS E055, ABB / FIMER UNO-DM-6.0-PLUS E077
CPS
CPS SCA50-100K-T Protect0720
Fronius
Fronius Galvo 412, Fronius Galvo 445, Fronius Galvo 482, Fronius Galvo 558, Fronius Galvo 705, Fronius Primo 412, Fronius Primo 417, Fronius Primo 436, Fronius Primo 438, Fronius Primo 480, Fronius Primo 481, Fronius Primo 482, Fronius Primo 483, Fronius Primo 558, Fronius Primo 705, Fronius Symo 412, Fronius Symo 417, Fronius Symo 436, Fronius Symo 438, Fronius Symo 445, Fronius Symo 480, Fronius Symo 481, Fronius Symo 482, Fronius Symo 483, Fronius Symo 558, Fronius Symo 559, Fronius Symo 564, Fronius Symo 608, Fronius Symo 705, Fronius Symo 768, Fronius Symo 773
Generac
Generac PWRcell Inverter 0X7700, Generac PWRcell Inverter 0X7701, Generac PWRcell Inverter 0X7702, Generac PWRcell Inverter 0X7703, Generac PWRcell Inverter 0X7704, Generac PWRcell Inverter 0X7705, Generac PWRcell Inverter 0X7706, Generac PWRcell Inverter 0X7707, Generac PWRcell Inverter 0X7708, Generac PWRcell Inverter 0X7709, Generac PWRcell Inverter 0X770A, Generac PWRcell Inverter 0X770B, Generac PWRcell Inverter 0X770C, Generac PWRcell Inverter 0X7721
KACO new energy
KACO new energy blueplanet TL3 159
SMA
SMA SB-US-40 10343, SMA SB-US-40 10344, SMA SB-US-40 1501, SMA SB-US-40 7347, SMA SB-US-40 7348, SMA SB-US-41 10343, SMA SB-US-41 10344, SMA SB-US-41 1501, SMA SB-US-41 7347, SMA SB-US-41 7348, SMA SBSE-US-50 1501, SMA PEAK3-US 1501, SMA PEAK3-US 7347, SMA PEAK3-US 7348, SMA CORE1-US 7105, SMA CORE1-US 7347, SMA CORE1-US 7348, SMA STP-TL-US 1501, SMA STP-X-US 1501, SMA SI-US F221, SMA SI-US F731, SMA SI-US F732, SMA SI-US F806
Schneider Electric
Schneider Electric CL125 023, Schneider Electric CL125 047
Solis
Solis S6-EH2P BatName-FAIL, Solis S6-EH3P30-60K BatName-FAIL, Solis S6-EH3P75-150K BatName-FAIL
Sungrow
Sungrow SG-CX-US 047
Yaskawa Solectria
Yaskawa Solectria SGI-XTM PAR Backup Err, Yaskawa Solectria SGI-XTM PAR Config Err, Yaskawa Solectria SGI-XTM Pw Brd Mismatch, Yaskawa Solectria XGI-1500 WARN-31

Same code in other families

Claims

defined_in

c1 drafted · lead fronius-primo-208-240-emanual-status-codes

reports

c2 drafted · lead Hardware component incompatibility

c3 drafted · lead Configuration error

mitigated_by

c4 drafted · lead Firmware update

Firmware update first; service technician if the code persists.

has_event_class

c5 drafted · lead Fault (device stops or needs intervention)

review note: support check: partial - The class 4 text is generic and does not tie 445 to class 4; the row states the inverter does…

has_production_effect

c6 drafted · lead Trip (production stops)

applies_to

c7 drafted · lead Fronius Primo 208-240

Data