Solar Lattice

Product

Fronius Primo 208-240

ID
prod:fronius-primo
IRI
https://solarlattice.org/kb/prod/fronius-primo
Status
active
Also known as
Primo 208-240
Category
Inverters
Make
fronius
Product level
family

The Fronius Primo 208-240 is a family of transformerless, utility-interactive inverters for permanent connection. CSA lists it as certified to U.S. standards. The certified models are 3.8-1, 5.0-1, 6.0-1, 7.6-1, 8.2-1, 10.0-1, 11.4-1, 12.5-1 and 15.0-1. The inverter connects to a 208 V, 220 V or 240 V nominal grid. The grid voltage tolerance is -12 % to +10 %. CEC efficiency ranges from 95.5 % to 97.0 %, depending on the model and the grid voltage. Reverse polarity protection and stand-alone operation (anti-islanding) protection are built in. Insulation monitoring is listed as built in on the 8.2-1 and 10.0-1 models. At high temperature the inverter protects itself by shifting its operating point and using active cooling.

Claims

instance_of

c1 drafted · lead Inverter

Certified as a permanently connected, transformerless utility-interactive inverter

implements

c2 verified · fact Reverse polarity protection

Listed as integrated in the technical data

verified by: review-workflowverified on: 2026-10-24

c3 verified · fact Anti-islanding

Listed as integrated stand-alone operation protection

verified by: review-workflowverified on: 2026-10-24

c4 drafted · lead Insulation monitoring

Listed as integrated for the 8.2-1 and 10.0-1 models

max_input_voltage

c5 drafted · lead nominal 1000 V

Conditions: Open-circuit at 14 °C (57.2 °F); models 3.8-1, 5.0-1 and 6.0-1 208-240

mppt_voltage_range

c6 drafted · lead 200–800 V

Conditions: Model 3.8-1 208-240

c7 drafted · lead 240–800 V

Conditions: Models 5.0-1 and 6.0-1 208-240

max_input_current

c8 drafted · lead nominal 18 A

Conditions: Per MPPT (MPPT1/MPPT2); models 3.8-1, 5.0-1 and 6.0-1 208-240

rated_power

c9 drafted · lead nominal 3800 W

Conditions: Model 3.8-1 208-240, nominal output power at 208, 220 and 240 V

review note: possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)

c10 drafted · lead nominal 5000 W

Conditions: Model 5.0-1 208-240, nominal output power at 208, 220 and 240 V

review note: possible conflict with c9 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)

c11 drafted · lead nominal 6000 W

Conditions: Model 6.0-1 208-240, nominal output power at 208, 220 and 240 V

review note: possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions)

nominal_voltage

c12 drafted · lead nominal 208 V

Conditions: Nominal grid voltage option (208 V/220 V/240 V)

review note: possible conflict with c13 (same source; check the conditions); possible conflict with c14 (same source; check the conditions)

c13 verified · fact nominal 220 V

Conditions: Nominal grid voltage option (208 V/220 V/240 V)

verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c12 (same source; check the conditions); possible conflict with c14 (same source; check the conditions)

c14 drafted · lead nominal 240 V

Conditions: Nominal grid voltage option (208 V/220 V/240 V)

review note: possible conflict with c12 (same source; check the conditions); possible conflict with c13 (same source; check the conditions)

efficiency

c15 drafted · lead nominal 96 PERCENT

Conditions: CEC efficiency, model 3.8-1 208-240 at 208 V

review note: possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions); possible conflict with c18 (same source; check the conditions); possible conflict with c19 (same source; check the conditions)

c16 drafted · lead nominal 95.5 PERCENT

Conditions: CEC efficiency, model 3.8-1 208-240 at 220 V and 240 V

review note: possible conflict with c15 (same source; check the conditions); possible conflict with c17 (same source; check the conditions); possible conflict with c18 (same source; check the conditions); possible conflict with c19 (same source; check the conditions)

c17 drafted · lead nominal 96.5 PERCENT

Conditions: CEC efficiency, models 5.0-1 and 6.0-1 208-240 at 208, 220 and 240 V

review note: possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions); possible conflict with c18 (same source; check the conditions)

c18 drafted · lead nominal 97 PERCENT

Conditions: CEC efficiency, models 7.6-1 and 8.2-1 208-240 at 208, 220 and 240 V

review note: possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions); possible conflict with c19 (same source; check the conditions)

c19 drafted · lead nominal 96.5 PERCENT

Conditions: CEC efficiency, model 10.0-1 208-240 at 208, 220 and 240 V

review note: possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions); possible conflict with c18 (same source; check the conditions)

Referenced by