No USB thumb drive inserted, No USB flash drive inserted

On Fronius Galvo, Primo and Symo inverters, status code 733 means the inverter finds no USB drive in its slot. The inverter shows it only as a warning message on the display. SMA devices report a similar message when no USB data carrier is detected, either because none is plugged in or because the one plugged in is not compatible. Check first that a USB drive is inserted and seated properly. If the code stays, contact a Fronius-trained service technician. Other USB codes point to different problems: 731 means the drive is not supported, so check its file system or replace it, and 732 means overcurrent at the drive. Code 736 is a read or write error, and code 738 means the log file could not be saved, for example because the drive is write-protected or full. Remove the drive only after the Data Transfer LED has stopped flashing and is off.

<!-- review notes

Claims

observed_as

c1 drafted · lead Inverter fault code display

Fronius Galvo, Primo and Symo inverters show status code 733 as a warning on the display when no USB drive is inserted.