Solar Lattice

Fault codes › Fronius › Fronius Symo UL (10.0-3 to 24.0-3 208-240/480)

Fronius Symo 461

Code
461
Shown as
Error in DSP data memory
Vendor severity
Class 4
ID
fc:fronius-symo-461
IRI
https://solarlattice.org/kb/fc/fronius-symo-461
Status
active
Also known as
461, Fronius 461, Error in DSP data memory
Category
Inverters
Class not stated
Production not stated
Clears not stated

Decoded

Reports internal memory error; look at digital signal processor.

What can be behind Internal memory error

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E051, ABB / FIMER PVS-60-TL E051
Canadian Solar
Canadian Solar 23-28KTL-CT EepromErr
Fronius
Fronius Galvo 721, Fronius Primo 461, Fronius Primo 721, Fronius Symo 721, Fronius Symo 772
KACO new energy
KACO new energy blueplanet TL3 128, KACO new energy blueplanet TL3 148, KACO new energy blueplanet TL3 207, KACO new energy blueplanet TL3 208, KACO new energy blueplanet TL3 209
SMA
SMA SC-CP-XT 6113
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL EepromErr, Yaskawa Solectria PVI-TL EepromErr

Same code in other families

Claims

defined_in

c1 drafted · lead fronius-symo-ul-emanual-status-codes

reports

c2 drafted · lead Internal memory error

affects

c3 drafted · lead Digital signal processor

applies_to

c4 drafted · lead Fronius Symo

Data