FailureMode
Flash memory failure
- ID
fm:flash-memory-failure
- IRI
https://solarlattice.org/kb/fm/flash-memory-failure
- Status
- active
- Also known as
- Flash Fault, Faulty Monitoring Unit
A flash memory failure means the flash storage on the inverter's monitoring board has run out of space or has developed bad sectors or blocks. On Huawei SUN2000 inverters it appears as alarm 61440 with Minor severity, shown as Flash Fault or Faulty Monitoring Unit depending on the model. If the alarm persists, replace the monitoring board or contact Huawei technical support.
<!-- review notes
- sentence 1: support check: partial - Causes (insufficient flash, bad sectors/blocks) are stated, but the passages do not define the failure as being specifically on the monitoring board's flash, though the fix implies it.
- sentence 2: support check: partial - Alarm 61440, Minor, and both names are stated, but 'depending on the model' is not stated in the passages, and the passages don't tie each name to specific models.
- sentence 1: review: partial - Insufficient flash memory and bad sectors or blocks are stated, but tying the flash to the monitoring board is only implied by the remedy (replace the monitoring board).
-->
Claims
affects
c1 drafted · lead
Monitoring board
caused_by
c2 verified · fact
Insufficient flash storage
The manuals list insufficient flash memory or flash space as a cause of alarm 61440.
verified by: review-workflowverified on: 2026-10-23
c3 verified · fact
Flash memory bad sectors
Bad sectors or bad blocks in the flash, or a faulty flash, are listed as a cause.
verified by: review-workflowverified on: 2026-10-23
presents_as
c4 drafted · lead
Internal memory error
Huawei SUN2000 inverters raise alarm ID 61440 with Minor severity, named Flash Fault or Faulty Monitoring Unit depending on model.
review note: support check: partial - Alarm 61440 Minor with names Flash Fault/Faulty Monitoring Unit is stated, but the passages never say it presents as an 'internal memory error' symptom, and the model dependence is not stated.
mitigated_by
c5 verified · fact
Monitoring board replacement
verified by: review-workflowverified on: 2026-10-23
c6 verified · fact
Monitoring device replacement
Applies when the monitoring board is built into the monitoring device.
verified by: review-workflowverified on: 2026-10-23
c7 verified · fact
Contact manufacturer service
Contact Huawei technical support if the fault is still there after the restart.
verified by: review-workflowverified on: 2026-10-23