Invalid external input signal

ID
symptom:invalid-external-signal
IRI
https://solarlattice.org/kb/symptom/invalid-external-signal
Status
active
Also known as
Incorrect input signal, invalid input status

On a Fronius Symo this symptom shows up as State 568 on the inverter display, which means the multifunctional power interface has received an incorrect input signal. The code only appears when the signal input function is set to Ext. signal and the trigger type is set to Warning. In that case the inverter keeps running and only shows the warning. If the trigger type is set to Ext. Stop instead, the same input condition switches the inverter off and the display shows State 668. The input can be set up as normally closed or normally open. Check that this setting matches how the external contact is actually wired. To clear it, acknowledge the state code and then check the devices connected to the multifunctional power interface. On SMA devices, a failure tolerance time parameter sets how long an invalid input status can last before it is recorded as a fault.