c1 drafted · lead Apparent power
Reactive power is the imaginary part of complex apparent power.
- Testing Power Elements in the SEL-351S, SEL-421, and SEL-700G
sec=h5h=3fed7bd11260 - GEH-7285
sec=h98h=8a0d3daeea45
Reactive power, written Q and measured in VAr, is the imaginary part of complex apparent power, while active power in watts is the real part; together they form the power triangle. Injecting reactive power raises voltage at the connection point and absorbing it lowers voltage, so an inverter running at an absorbing power factor can offset the voltage rise caused by exporting real power. In constant VAr mode the inverter generates or absorbs a fixed amount of reactive power on command, much like utility switched capacitors; if the inverter's MVA rating would be exceeded, reactive output is capped without cutting active power. Large PV plants may be told by grid operators to absorb or supply reactive power at the grid connection point to help regulate voltage and stabilize the grid. Inverters and plant controllers expose reactive power as both a measured value and a setpoint, for example manual VAr setpoints, maximum reactive power limits, and Volt-VAr curve points set in percent under each grid code setting.
related_toc1 drafted · lead Apparent power
Reactive power is the imaginary part of complex apparent power.
sec=h5 h=3fed7bd11260sec=h98 h=8a0d3daeea45c2 drafted · lead Active power
Active power is the real part and reactive power the imaginary part of apparent power.
sec=h5 h=3fed7bd11260sec=h98 h=8a0d3daeea45c3 verified · fact Power factor
Changing the power factor setpoint changes the inverter's reactive power output.
sec=4.2.1 h=3eed03bbd339sec=h98 h=8a0d3daeea45verified by: review-workflowverified on: 2026-10-24
c5 drafted · lead Constant reactive power mode
sec=4.2.2.2 h=7f80beaf616fsec=4.5.2 h=6a065d90b256c6 drafted · lead Constant power factor mode
sec=4.2.1 h=3eed03bbd339Volt-VAr curve points are set as reactive power percentages; one vendor limits output to 60% of nameplate.
sec=h28 h=b059d5d98e72tbl=21.r14 h=90b18f19d4f5tbl=20.r14 h=90b18f19d4f5review note: support check: partial - Q(U) points as percentages and 60% nameplate limit are stated, but the 60% limit is not attributed to one vendor and curve-point wording is implicit.
explainsc4 drafted · lead Voltage rise
Injecting reactive power raises voltage at the point of injection; absorbing it lowers voltage.
sec=4.2.1 h=3eed03bbd339related_to c1related_to c2related_to c10related_to c7related_to c2related_to c6related_to c3related_to c2related_to c2explains c1