Fault codes › ABB / FIMER › TRIO-20.0/27.6-TL-OUTD(-US)
ABB / FIMER TRIO-20.0-27.6-TL CODE:01
- Code
CODE:01
- Page
- 114
- ID
fc:abb-trio-20-27-6-tl-outd-code01
- IRI
https://solarlattice.org/kb/fc/abb-trio-20-27-6-tl-outd-code01
- Status
- active
- Also known as
- CODE:01, code01, ABB / FIMER CODE:01
- Category
- Inverters
Class
not stated
Clears
not stated
Decoded
Reports grid overfrequency; confirm with inverter settings review.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL W006, ABB / FIMER PVS-60-TL CODE:01, ABB / FIMER PVS-60-TL W006, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:01, ABB / FIMER UNO-DM-3.3-5.0-PLUS W006, ABB / FIMER UNO-DM-6.0-PLUS CODE:01, ABB / FIMER UNO-DM-6.0-PLUS W006
- Canadian Solar
- Canadian Solar 125K-T600GL02 OV-G-F, Canadian Solar 125KTL-GS-E OV-G-F, Canadian Solar 185-255K OV-G-F01/02, Canadian Solar 25-40K-T480GL01 OV-G-F, Canadian Solar 25-40KTL-GS-FL OV-G-F, Canadian Solar 50-66K-T480GL01 OV-G-F, Canadian Solar 50-66KTL-GS-FL OV-G-F, Canadian Solar 75-100K-T480GL02 OV-G-F
- Fronius
- Fronius Galvo 105, Fronius Galvo 560, Fronius Primo 105, Fronius Primo 560, Fronius Symo 105, Fronius Symo 560
- Huawei
- Huawei SUN2000-100KTL-USH0 2036, Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
- KACO new energy
- KACO new energy blueplanet TL3 49
- SMA
- SMA SBSE-US-50 507, SMA PEAK3-US 0503, SMA PEAK3-US 507, SMA STP-X-US 507, SMA SC-CP-XT 0503, SMA SC-CP-XT 0505, SMA SI-US W327, SMA SI-US W328, SMA SI-US W329, SMA SI-US W330
- Schneider Electric
- Schneider Electric CL125 008
- Solis
- Solis 1P-4G-US OV-G-F, Solis 3P-5G-US OV-G-F01/02, Solis RHI-1P-HV OV-G-F01/02, Solis S5-GC OV-G-F, Solis S6-EH1P OV-G-F01/02, Solis S6-EH2P OV-G-F01, Solis S6-EH2P OV-G-F02, Solis S6-EH3P30-60K OV-G-F01, Solis S6-EH3P30-60K OV-G-F02, Solis S6-EH3P75-150K OV-G-F01, Solis S6-EH3P75-150K OV-G-F02, Solis S6-GC OV-G-F, Solis S6-GU OV-G-F
- Sungrow
- Sungrow SG-CX-US 008, Sungrow SG200HX 008, Sungrow SG250HX 8, Sungrow SG350HX 008
- Yaskawa Solectria
- Yaskawa Solectria SGI-XTM Fac High, Yaskawa Solectria XGI-1500-1MW WARN-7, Yaskawa Solectria XGI-1500-1MW WARN-8, Yaskawa Solectria XGI-1500-DCG WARN-7, Yaskawa Solectria XGI-1500-DCG WARN-8, Yaskawa Solectria XGI-1500 WARN-7, Yaskawa Solectria XGI-1500 WARN-8
Same code in other families
Claims
defined_in
c1 drafted · lead
FIMER TRIO-20.0-27.6-TL-OUTD Product Manual RevG
reports
c2 drafted · lead
Grid overfrequency
review note: support check: partial - It is a power limitation due to over-frequency, but described as a user-set derating rather than an actual grid overfrequency report.
has_production_effect
c3 drafted · lead
Derate (output reduced or limited)
Limit percentage is variable and set by parameter; printed values are only examples.
detected_by
c4 drafted · lead
Inverter settings review
applies_to
c5 drafted · lead
TRIO-20.0/27.6-TL-OUTD string inverter
Data