Canadian Solar 185-255K OV-G-F01/02
- Code
OV-G-F01/02
- Shown as
- Over grid frequency
- Page
- 32
- ID
fc:canadian-solar-185-255k-ovgf0102
- IRI
https://solarlattice.org/kb/fc/canadian-solar-185-255k-ovgf0102
- Status
- active
- Also known as
- OV-G-F01/02, ovgf0102, Canadian Solar OV-G-F01/02, Over grid frequency
- Category
- Inverters
Class
not stated
Production
not stated
Clears
not stated
Decoded
Reports grid overfrequency; do: inverter parameter adjustment.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL W006, ABB / FIMER PVS-60-TL CODE:01, ABB / FIMER PVS-60-TL W006, ABB / FIMER TRIO-20.0-27.6-TL CODE:01, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:01, ABB / FIMER UNO-DM-3.3-5.0-PLUS W006, ABB / FIMER UNO-DM-6.0-PLUS CODE:01, ABB / FIMER UNO-DM-6.0-PLUS W006
- Canadian Solar
- Canadian Solar 125K-T600GL02 OV-G-F, Canadian Solar 125KTL-GS-E OV-G-F, Canadian Solar 25-40K-T480GL01 OV-G-F, Canadian Solar 25-40KTL-GS-FL OV-G-F, Canadian Solar 50-66K-T480GL01 OV-G-F, Canadian Solar 50-66KTL-GS-FL OV-G-F, Canadian Solar 75-100K-T480GL02 OV-G-F
- Fronius
- Fronius Galvo 105, Fronius Galvo 560, Fronius Primo 105, Fronius Primo 560, Fronius Symo 105, Fronius Symo 560
- Huawei
- Huawei SUN2000-100KTL-USH0 2036, Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
- KACO new energy
- KACO new energy blueplanet TL3 49
- SMA
- SMA SBSE-US-50 507, SMA PEAK3-US 0503, SMA PEAK3-US 507, SMA STP-X-US 507, SMA SC-CP-XT 0503, SMA SC-CP-XT 0505, SMA SI-US W327, SMA SI-US W328, SMA SI-US W329, SMA SI-US W330
- Schneider Electric
- Schneider Electric CL125 008
- Solis
- Solis 1P-4G-US OV-G-F, Solis 3P-5G-US OV-G-F01/02, Solis RHI-1P-HV OV-G-F01/02, Solis S5-GC OV-G-F, Solis S6-EH1P OV-G-F01/02, Solis S6-EH2P OV-G-F01, Solis S6-EH2P OV-G-F02, Solis S6-EH3P30-60K OV-G-F01, Solis S6-EH3P30-60K OV-G-F02, Solis S6-EH3P75-150K OV-G-F01, Solis S6-EH3P75-150K OV-G-F02, Solis S6-GC OV-G-F, Solis S6-GU OV-G-F
- Sungrow
- Sungrow SG-CX-US 008, Sungrow SG200HX 008, Sungrow SG250HX 8, Sungrow SG350HX 008
- Yaskawa Solectria
- Yaskawa Solectria SGI-XTM Fac High, Yaskawa Solectria XGI-1500-1MW WARN-7, Yaskawa Solectria XGI-1500-1MW WARN-8, Yaskawa Solectria XGI-1500-DCG WARN-7, Yaskawa Solectria XGI-1500-DCG WARN-8, Yaskawa Solectria XGI-1500 WARN-7, Yaskawa Solectria XGI-1500 WARN-8
Claims
defined_in
c1 drafted · lead
CSI Installation Manual 185-255K USA V1.1 20211119
reports
c2 drafted · lead
Grid overfrequency
mitigated_by
c3 drafted · lead
Inverter parameter adjustment
Only if the utility permits changing the protection limit.
applies_to
c4 drafted · lead
CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U
Data