Solar Lattice

Product

CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U

ID
prod:canadian-solar-185-255k
IRI
https://solarlattice.org/kb/prod/canadian-solar-185-255k
Status
active
Also known as
CSI-185K-T600GL02-U, CSI-185K-T600GL03-U, CSI-255K-T800GL02-U, CSI-255K-T800GL03-U
Category
Inverters
Make
canadian-solar
Product level
family

This family covers four Canadian Solar three-phase, grid-tied, transformerless string inverters: CSI-185K-T600GL02/03-U and CSI-255K-T800GL02/03-U. They convert PV array DC power into AC to supply local loads and feed the grid. The 185K models are rated for a 600 V grid and the 255K models for an 800 V grid, both at 60 Hz. The maximum DC input is 1500 V. Maximum output current is 178.0 A for the 185K models and 184.0 A for the 255K models. The manual lists a 250 A grid overcurrent protection device for each model. The GL02 models take 14 inputs of up to 26 A each and ship with 28 DC connectors. The 185K GL03 model takes 12 inputs of up to 30 A each, and the GL03 models ship with 24 DC connectors. The DC connectors are MC4 type. Maximum efficiency is 99.0 percent and EU efficiency is 98.5 percent. Communication is over RS485, with power line communication as an option. Each unit has a 2x20 LCD display and uses intelligent redundant cooling. The standard warranty is 5 years and can be extended to 20 years.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead Canadian Solar

Manual published by CSI Solar Co., Ltd.

instance_of

c2 drafted · lead Inverter

Three-phase inverter converting PV DC power to AC for local loads and the grid

compatible_with

c3 drafted · lead Grid-tied PV without storage

Scope: applications on-grid

uses_protocol

c4 drafted · lead RS-485

Conditions: Stated for CSI-185K-T600GL02-U and CSI-255K-T800GL02-U

c5 drafted · lead Power line communication

Conditions: Optional; stated for the GL02 models

PLC is listed as an optional communication connection

max_input_voltage

c6 drafted · lead nominal 1500 V

Conditions: Maximum DC input voltage, CSI-185K-T600GL02-U

c7 drafted · lead nominal 1500 V

Conditions: Maximum DC input voltage, CSI-255K-T800GL02-U

nominal_voltage

c8 drafted · lead nominal 950 V

Conditions: Rated DC voltage, CSI-185K-T600GL02-U

review note: possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)

c9 drafted · lead nominal 1080 V

Conditions: Rated DC voltage, CSI-255K-T800GL02-U

review note: possible conflict with c8 (same source; check the conditions); possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)

c10 drafted · lead nominal 600 V

Conditions: Rated AC grid voltage (3/PE), CSI-185K-T600GL02-U and GL03-U

review note: possible conflict with c8 (same source; check the conditions); possible conflict with c9 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)

c11 drafted · lead nominal 800 V

Conditions: Rated AC grid voltage (3/PE), CSI-255K-T800GL02-U and GL03-U

review note: possible conflict with c8 (same source; check the conditions); possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions)

max_input_current

c12 drafted · lead nominal 26 A

Conditions: Per input, listed as 14*26 A, CSI-185K-T600GL02-U

review note: possible conflict with c14 (same source; check the conditions)

c13 verified · fact nominal 26 A

Conditions: Per input, listed as 14*26 A, CSI-255K-T800GL02-U

verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c14 (same source; check the conditions)

c14 drafted · lead nominal 30 A

Conditions: Per input, listed as 12*30 A, CSI-185K-T600GL03-U

review note: possible conflict with c12 (same source; check the conditions); possible conflict with c13 (same source; check the conditions)

rated_output_current

c15 drafted · lead nominal 178 A

Conditions: Maximum output current, CSI-185K-T600GL02-U and GL03-U; grid OCPD 250 A

review note: possible conflict with c16 (same source; check the conditions)

c16 drafted · lead nominal 184 A

Conditions: Rated/maximum output current, CSI-255K-T800GL02-U and GL03-U; grid OCPD 250 A

review note: possible conflict with c15 (same source; check the conditions)

frequency

c17 drafted · lead nominal 60 HZ

Conditions: Rated grid frequency, CSI-185K-T600GL02-U

c18 drafted · lead nominal 60 HZ

Conditions: Rated grid frequency, CSI-255K-T800GL02-U

warranty_term

c19 drafted · lead ≤ 20, nominal 5 YR

Conditions: 5 years standard, extendable to 20 years; stated for CSI-185K-T600GL02-U