Fault codes › Sungrow › Sungrow SG250HX
Sungrow SG250HX 8
- Code
8
- Shown as
- Grid Overfrequency
- Page
- 91
- ID
fc:sungrow-sg250hx-8
- IRI
https://solarlattice.org/kb/fc/sungrow-sg250hx-8
- Status
- active
- Also known as
- 8, Sungrow 8, Grid Overfrequency
- Category
- Inverters
Class
fault drafted · lead
Production
stops drafted · lead
Decoded
Reports grid overfrequency; confirm with grid frequency measurement.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL W006, ABB / FIMER PVS-60-TL CODE:01, ABB / FIMER PVS-60-TL W006, ABB / FIMER TRIO-20.0-27.6-TL CODE:01, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:01, ABB / FIMER UNO-DM-3.3-5.0-PLUS W006, ABB / FIMER UNO-DM-6.0-PLUS CODE:01, ABB / FIMER UNO-DM-6.0-PLUS W006
- Canadian Solar
- Canadian Solar 125K-T600GL02 OV-G-F, Canadian Solar 125KTL-GS-E OV-G-F, Canadian Solar 185-255K OV-G-F01/02, Canadian Solar 25-40K-T480GL01 OV-G-F, Canadian Solar 25-40KTL-GS-FL OV-G-F, Canadian Solar 50-66K-T480GL01 OV-G-F, Canadian Solar 50-66KTL-GS-FL OV-G-F, Canadian Solar 75-100K-T480GL02 OV-G-F
- Fronius
- Fronius Galvo 105, Fronius Galvo 560, Fronius Primo 105, Fronius Primo 560, Fronius Symo 105, Fronius Symo 560
- Huawei
- Huawei SUN2000-100KTL-USH0 2036, Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
- KACO new energy
- KACO new energy blueplanet TL3 49
- SMA
- SMA SBSE-US-50 507, SMA PEAK3-US 0503, SMA PEAK3-US 507, SMA STP-X-US 507, SMA SC-CP-XT 0503, SMA SC-CP-XT 0505, SMA SI-US W327, SMA SI-US W328, SMA SI-US W329, SMA SI-US W330
- Schneider Electric
- Schneider Electric CL125 008
- Solis
- Solis 1P-4G-US OV-G-F, Solis 3P-5G-US OV-G-F01/02, Solis RHI-1P-HV OV-G-F01/02, Solis S5-GC OV-G-F, Solis S6-EH1P OV-G-F01/02, Solis S6-EH2P OV-G-F01, Solis S6-EH2P OV-G-F02, Solis S6-EH3P30-60K OV-G-F01, Solis S6-EH3P30-60K OV-G-F02, Solis S6-EH3P75-150K OV-G-F01, Solis S6-EH3P75-150K OV-G-F02, Solis S6-GC OV-G-F, Solis S6-GU OV-G-F
- Sungrow
- Sungrow SG-CX-US 008, Sungrow SG200HX 008, Sungrow SG350HX 008
- Yaskawa Solectria
- Yaskawa Solectria SGI-XTM Fac High, Yaskawa Solectria XGI-1500-1MW WARN-7, Yaskawa Solectria XGI-1500-1MW WARN-8, Yaskawa Solectria XGI-1500-DCG WARN-7, Yaskawa Solectria XGI-1500-DCG WARN-8, Yaskawa Solectria XGI-1500 WARN-7, Yaskawa Solectria XGI-1500 WARN-8
Same code in other families
Claims
defined_in
c1 drafted · lead
SG250HX-US-UEN-Ver17-202203
reports
c2 drafted · lead
Grid overfrequency
has_event_class
c3 drafted · lead
Fault (device stops or needs intervention)
review note: support check: partial - The passages show it is a listed fault code in the troubleshooting table, but they give no explicit fault-versus-warning classification.
has_production_effect
c4 drafted · lead
Trip (production stops)
review note: support check: partial - The inverter reconnects after the grid returns to normal, which implies it disconnected, but the passages don't explicitly say production stops.
has_recovery
c5 drafted · lead
Auto-reset (clears by itself)
Further checks only if the fault repeats.
detected_by
c6 verified · fact
Grid frequency measurement
verified by: review-workflowverified on: 2026-10-20
applies_to
c7 drafted · lead
Sungrow SG250HX-US
Data