Fault codes › Solis › Solis S6-GC(25-60)K-US
Solis S6-GC UN-G-F
- Code
UN-G-F
- Shown as
- Grid under frequency
- Page
- 73
- ID
fc:solis-s6-gc-us-ungf
- IRI
https://solarlattice.org/kb/fc/solis-s6-gc-us-ungf
- Status
- active
- Also known as
- UN-G-F, ungf, Solis UN-G-F, Grid under frequency
- Category
- Inverters
Class
not stated
Production
not stated
Clears
not stated
Decoded
Reports grid underfrequency; confirm with grid frequency measurement; do: grid settings check, utility company consultation, inverter restart.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL W007, ABB / FIMER PVS-60-TL W007, ABB / FIMER UNO-DM-3.3-5.0-PLUS W007, ABB / FIMER UNO-DM-6.0-PLUS W007
- Canadian Solar
- Canadian Solar 185-255K UN-G-F01/02
- Fronius
- Fronius Galvo 106, Fronius Primo 106, Fronius Symo 106
- Huawei
- Huawei SUN2000-100KTL-USH0 2037, Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
- KACO new energy
- KACO new energy blueplanet TL3 48
- SMA
- SMA PEAK3-US 0502, SMA SC-CP-XT 0502, SMA SC-CP-XT 0504, SMA SI-US W323, SMA SI-US W324, SMA SI-US W325, SMA SI-US W326
- Schneider Electric
- Schneider Electric CL125 009
- Solis
- Solis 1P-4G-US UN-G-F, Solis 3P-5G-US UN-G-F01/02, Solis RHI-1P-HV UN-G-F01/02, Solis S6-EH1P UN-G-F01/02, Solis S6-EH2P LmtByUnFr, Solis S6-EH2P UN-G-F01, Solis S6-EH2P UN-G-F02, Solis S6-EH3P30-60K LmtByUnFr, Solis S6-EH3P30-60K UN-G-F01, Solis S6-EH3P30-60K UN-G-F02, Solis S6-EH3P75-150K LmtByUnFr, Solis S6-EH3P75-150K UN-G-F01, Solis S6-EH3P75-150K UN-G-F02, Solis S6-GU UN-G-F
- Sungrow
- Sungrow SG-CX-US 009, Sungrow SG200HX 009, Sungrow SG250HX 9, Sungrow SG350HX 009
- Yaskawa Solectria
- Yaskawa Solectria SGI-XTM Fac Low, Yaskawa Solectria SGI-XTM Fac Very Low, Yaskawa Solectria XGI-1500-1MW WARN-5, Yaskawa Solectria XGI-1500-1MW WARN-6, Yaskawa Solectria XGI-1500-DCG WARN-5, Yaskawa Solectria XGI-1500-DCG WARN-6, Yaskawa Solectria XGI-1500 WARN-5, Yaskawa Solectria XGI-1500 WARN-6
Same code in other families
Claims
defined_in
c1 drafted · lead
Solis S6-GC30K-LV-US Manual V1.2
reports
c2 drafted · lead
Grid underfrequency
detected_by
c3 drafted · lead
Grid frequency measurement
mitigated_by
c4 drafted · lead
Grid settings check
c5 drafted · lead
Utility company consultation
Lower frequency limit adjusted only with utility permission.
c6 drafted · lead
Inverter restart
applies_to
c7 drafted · lead
Solis S6-GC(25-60)K-US
Data