Fault codes › Sungrow › Sungrow SG350HX-US
Sungrow SG350HX 009
- Code
009
- Shown as
- Grid Underfrequency
- Page
- 88
- ID
fc:sungrow-sg350hx-9
- IRI
https://solarlattice.org/kb/fc/sungrow-sg350hx-9
- Status
- active
- Also known as
- 009, 9, Sungrow 009, Grid Underfrequency
- Category
- Inverters
Class
fault verified · fact
Production
not stated
Clears
not stated
Decoded
Reports grid underfrequency; confirm with inverter settings review; do: grid settings check.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL W007, ABB / FIMER PVS-60-TL W007, ABB / FIMER UNO-DM-3.3-5.0-PLUS W007, ABB / FIMER UNO-DM-6.0-PLUS W007
- Canadian Solar
- Canadian Solar 185-255K UN-G-F01/02
- Fronius
- Fronius Galvo 106, Fronius Primo 106, Fronius Symo 106
- Huawei
- Huawei SUN2000-100KTL-USH0 2037, Huawei SUN2000-25-30KTL-US 305, Huawei SUN2000-45KTL-US-HV-D0 305
- KACO new energy
- KACO new energy blueplanet TL3 48
- SMA
- SMA PEAK3-US 0502, SMA SC-CP-XT 0502, SMA SC-CP-XT 0504, SMA SI-US W323, SMA SI-US W324, SMA SI-US W325, SMA SI-US W326
- Schneider Electric
- Schneider Electric CL125 009
- Solis
- Solis 1P-4G-US UN-G-F, Solis 3P-5G-US UN-G-F01/02, Solis RHI-1P-HV UN-G-F01/02, Solis S6-EH1P UN-G-F01/02, Solis S6-EH2P LmtByUnFr, Solis S6-EH2P UN-G-F01, Solis S6-EH2P UN-G-F02, Solis S6-EH3P30-60K LmtByUnFr, Solis S6-EH3P30-60K UN-G-F01, Solis S6-EH3P30-60K UN-G-F02, Solis S6-EH3P75-150K LmtByUnFr, Solis S6-EH3P75-150K UN-G-F01, Solis S6-EH3P75-150K UN-G-F02, Solis S6-GC UN-G-F, Solis S6-GU UN-G-F
- Sungrow
- Sungrow SG-CX-US 009, Sungrow SG200HX 009, Sungrow SG250HX 9
- Yaskawa Solectria
- Yaskawa Solectria SGI-XTM Fac Low, Yaskawa Solectria SGI-XTM Fac Very Low, Yaskawa Solectria XGI-1500-1MW WARN-5, Yaskawa Solectria XGI-1500-1MW WARN-6, Yaskawa Solectria XGI-1500-DCG WARN-5, Yaskawa Solectria XGI-1500-DCG WARN-6, Yaskawa Solectria XGI-1500 WARN-5, Yaskawa Solectria XGI-1500 WARN-6
Same code in other families
Claims
defined_in
c1 drafted · lead
Sungrow SG350HX-US User Manual
reports
c2 drafted · lead
Grid underfrequency
has_event_class
c3 verified · fact
Fault (device stops or needs intervention)
verified by: review-workflowverified on: 2026-10-23review note: support check: partial - Row is called a fault and requires contacting Sungrow, but the passages do not classify it explicitly as fault vs…
detected_by
c4 drafted · lead
Inverter settings review
mitigated_by
c5 drafted · lead
Grid settings check
applies_to
c6 drafted · lead
Sungrow SG350HX-US