Solar Lattice

FailureMode

Incorrect or unset grid code

ID
fm:grid-code-misconfiguration
IRI
https://solarlattice.org/kb/fm/grid-code-misconfiguration
Status
active
Also known as
wrong country data set, country data set not set, No country data set set, wrong grid type, country code not set, no country data set, incorrect country setup, SMA default, country data set, grid type, country standard, Grid code, country code

This fault happens when the inverter's grid code, country data set or grid type is missing or does not match the country, the local standards or the site. A wrong setting can disturb the PV system and cause problems with the grid operator. The grid code changes grid-related parameters such as the power factor and reactive power settings, so the inverter can run with the wrong protection and control behavior. To confirm, open the Grid monitoring parameter group and check the Set country standard parameter. To fix it, select the country data set or grid code that fits the site and its application. After the first 10 operating hours, SMA inverters need the installer's SMA Grid Guard code before grid parameters can be changed, and a wrong code leaves them locked. If you are not sure which standard applies, contact the grid operator before you change the setting.

<!-- review notes

Claims

affects

c1 drafted · lead Inverter

The grid code or country data set is an inverter parameter (for example Set country standard under Grid monitoring).

caused_by

c2 drafted · lead Installation error

The installer picks a country data set or grid type that does not fit the country, the local standards or the system properties.

presents_as

c3 drafted · lead Grid instability

SMA warns that a wrong country data set or grid type can disturb the PV system and cause problems with the grid operator.

review note: support check: partial - Passages say wrong data set/grid type can disturb the PV system and cause grid operator problems, but not literally 'grid instability'.

c4 drafted · lead Parameter change rejected

When you try to correct the setting with a wrong SMA Grid Guard code, event 9002 appears and the grid parameters stay locked.

review note: support check: partial - Event 9002 with locked parameters on a wrong Grid Guard code is stated, but its link to correcting an incorrect grid code is inferred, not stated.

detected_by

c5 drafted · lead Inverter settings review

Check the Set country standard parameter (channel CntrySet or Country) in the Grid monitoring group.

review note: support check: partial - Passages identify the Set country standard parameter and its group/channels, but only as the setting procedure, not as a detection/review step.

mitigated_by

c6 verified · fact Grid settings check

Set the required country data set or grid code for the country or region and the application. SolarEdge sets the general USA country code to get typical IEEE 1547 settings.

verified by: review-workflowverified on: 2026-10-24

c7 verified · fact Utility company consultation

Contact the grid operator if you are unsure which standards and directives apply.

verified by: review-workflowverified on: 2026-10-24

c8 verified · fact Correct access code entry

After the first 10 operating hours, the grid-relevant parameters can only be changed with the personal SMA Grid Guard code.

verified by: review-workflowverified on: 2026-10-24