Switching cycle limit reached

ID
symptom:switch-cycle-limit
IRI
https://solarlattice.org/kb/symptom/switch-cycle-limit
Status
active

This symptom is a wear warning: the inverter counts how often a switching device has operated and raises an event when the count nears or reaches its rated limit. On a Sunny Central CP XT, event 7709 means the DC switchgear has used 90% of its switch cycles, and event 7710 means it has used all of them. Event 7714 is a separate event: the GFDI has reached its maximum number of switch cycles. The manual lists an inverter behavior time of 10 s for 7709 and 30 s for 7710 and 7714. For the DC switchgear events, the corrective action is to contact the SMA Service Line. For the GFDI event, the GFDI should be replaced. First, read the event number in the inverter's event log to find out which device is worn: the DC switchgear or the GFDI. As a comparison, SMA rates the switch in some string inverters for a minimum electrical endurance of 100000 switching cycles, as long as its maximum switching voltage and current are not exceeded.