Solar Lattice

Fault codes › SMA › Sunny Tripower X 13-30-US (STP xx-US-50)

SMA STP-X-US 6401

Code
6401
Shown as
Self-diagnosis > Interference device
Page
89
ID
fc:sma-stp-x-us-50-6401
IRI
https://solarlattice.org/kb/fc/sma-stp-x-us-50-6401
Status
active
Also known as
6401, SMA 6401, Self-diagnosis > Interference device
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears by itself drafted · lead

Decoded

Reports internal device fault; look at insulation monitoring device, PV array; confirm with insulation resistance testing, DC voltage measurement; do: string isolation, DC wiring check, inverter replacement.

What can be behind Internal device fault

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E012, ABB / FIMER PVS-166-175-TL E024, ABB / FIMER PVS-166-175-TL E034, ABB / FIMER PVS-166-175-TL E049, ABB / FIMER PVS-166-175-TL E009, ABB / FIMER PVS-60-TL E012, ABB / FIMER PVS-60-TL E024, ABB / FIMER PVS-60-TL E034, ABB / FIMER PVS-60-TL E049, ABB / FIMER PVS-60-TL E081, ABB / FIMER PVS-60-TL E009, ABB / FIMER TRIO-20.0-27.6-TL E012, ABB / FIMER TRIO-20.0-27.6-TL E024, ABB / FIMER TRIO-20.0-27.6-TL E034, ABB / FIMER TRIO-20.0-27.6-TL E049, ABB / FIMER TRIO-20.0-27.6-TL E009, ABB / FIMER UNO-DM-3.3-5.0-PLUS E012, ABB / FIMER UNO-DM-3.3-5.0-PLUS E024, ABB / FIMER UNO-DM-3.3-5.0-PLUS E034, ABB / FIMER UNO-DM-3.3-5.0-PLUS E049, ABB / FIMER UNO-DM-3.3-5.0-PLUS E081, ABB / FIMER UNO-DM-3.3-5.0-PLUS E009, ABB / FIMER UNO-DM-6.0-PLUS E012, ABB / FIMER UNO-DM-6.0-PLUS E024, ABB / FIMER UNO-DM-6.0-PLUS E034, ABB / FIMER UNO-DM-6.0-PLUS E049, ABB / FIMER UNO-DM-6.0-PLUS E081, ABB / FIMER UNO-DM-6.0-PLUS E009
CPS
CPS SCA25KTL-208 Fault0060, CPS SCA25KTL-208 Protect0150, CPS SCA25KTL-480 Fault0060, CPS SCA25KTL-480 Protect0150, CPS SCA36KTL EepromErr, CPS SCA36KTL Fault0060, CPS SCA36KTL Protect0100, CPS SCA36KTL Protect0150, CPS SCA36KTL Protect0180, CPS SCA50-100K-T PFault0010, CPS SCA50-100K-T PFault0130, CPS SCA50-100K-T PFault0070, CPS SCA50-100K-T Protect1050, CPS SCA50-100K-T Protect0150, CPS SCA50-100K-T Protect0330, CPS SCA50-100K-T Protect0730, CPS SCA50-100K-T Protect0740, CPS SCA50-60KTL EepromErr, CPS SCA50-60KTL Fault0060, CPS SCA50-60KTL Protect0100, CPS SCA50-60KTL Protect0150, CPS SCA50-60KTL Protect0180, CPS SCH100-125KTL Fault0060, CPS SCH100-125KTL Protect0150, CPS SCH125KTL-AIO Fault0060, CPS SCH125KTL-AIO Protect0150, CPS SCH200-250K-T Fault0740, CPS SCH275KTL Fault0060, CPS SCH275KTL Protect0150, CPS SCH350KTL Fault0060, CPS SCH350KTL Protect0150
Canadian Solar
Canadian Solar 125K-T600GL02 IN I-PRO, Canadian Solar 125KTL-GS-E IN I-PRO, Canadian Solar 185-255K INI-FAULT, Canadian Solar 23-28KTL-CT IntFault0010-0150, Canadian Solar 23-28KTL-CT IntProtect0010-0620, Canadian Solar 25-40K-T480GL01 INI-FAULT, Canadian Solar 25-40KTL-GS-FL IN I-PRO, Canadian Solar 50-66K-T480GL01 INI-FAULT, Canadian Solar 50-66KTL-GS-FL IN I-PRO, Canadian Solar 75-100K-T480GL02 INI-FAULT
Fronius
Fronius Primo 426-428, Fronius Primo 431, Fronius Symo 426-428, Fronius Symo 431, Fronius Symo 518, Fronius Symo 760
Huawei
Huawei SUN2000-100KTL-USH0 2064, Huawei SUN2000-25-30KTL-US 400, Huawei SUN2000-25-30KTL-US 410, Huawei SUN2000-45KTL-US-HV-D0 400, Huawei SUN2000-45KTL-US-HV-D0 410
KACO new energy
KACO new energy blueplanet TL3 31
SMA
SMA SBSE-US-50 6001-6499, SMA SBSE-US-50 6606, SMA SBSE-US-50 6633, SMA SBSE-US-50 7702, SMA SBSE-US-50 7703, SMA SBSE-US-50 9107, SMA PEAK3-US 6001-6499, SMA PEAK3-US 6438, SMA PEAK3-US 7701, SMA PEAK3-US 9107, SMA CORE1-US 6002-6412, SMA CORE1-US 6107, SMA CORE1-US 7702, SMA STP-TL-US 6001-6438, SMA STP-TL-US 6606, SMA STP-TL-US 7701-7703, SMA STP-X-US 6001-6499, SMA STP-X-US 6101, SMA STP-X-US 6107, SMA STP-X-US 6202, SMA STP-X-US 6422, SMA STP-X-US 6438, SMA STP-X-US 7702, SMA STP-X-US 7703, SMA SC-CP-XT 6115, SMA SC-CP-XT 6117, SMA SC-CP-XT 6120, SMA SC-CP-XT 6121, SMA SC-CP-XT 6122, SMA SC-CP-XT 6422, SMA SC-CP-XT 6443, SMA SC-CP-XT 7601, SMA SI-US F781, SMA SI-US W713
Schneider Electric
Schneider Electric CL125 041, Schneider Electric CL125 044, Schneider Electric CL125 048, Schneider Electric CL125 049, Schneider Electric CL125 050, Schneider Electric CL125 060
Solis
Solis 1P-4G-US INI-FAULT, Solis 3P-5G-US INI-FAULT, Solis RHI-1P-HV INI-FAULT, Solis S5-GC INI-FAULT, Solis S6-EH1P INI-FAULT, Solis S6-EH2P INI-FAULT, Solis S6-EH3P30-60K INI-FAULT, Solis S6-EH3P75-150K INI-FAULT, Solis S6-GC INI-FAULT, Solis S6-GC PID Repairing, Solis S6-GU INI-FAULT, Solis S6-GU PID Repairing
Sungrow
Sungrow SG-CX-US 011, Sungrow SG-CX-US 116-117, Sungrow SG-CX-US 019-020, Sungrow SG-CX-US 021-022, Sungrow SG-CX-US 024-025, Sungrow SG-CX-US 030-034, Sungrow SG-CX-US 038, Sungrow SG-CX-US 040-042, Sungrow SG-CX-US 044-046, Sungrow SG-CX-US 048-050, Sungrow SG-CX-US 053-056, Sungrow SG-CX-US 059-060, Sungrow SG-CX-US 076, Sungrow SG200HX 100-105, Sungrow SG200HX 107-114, Sungrow SG200HX 011, Sungrow SG200HX 116-124, Sungrow SG200HX 1616, Sungrow SG200HX 19-25, Sungrow SG200HX 200-211, Sungrow SG200HX 248-255, Sungrow SG200HX 030-034, Sungrow SG200HX 300-322, Sungrow SG200HX 324-328, Sungrow SG200HX 038, Sungrow SG200HX 040-042, Sungrow SG200HX 44-50, Sungrow SG200HX 52-58, Sungrow SG200HX 60-69, Sungrow SG200HX 85, Sungrow SG200HX 92, Sungrow SG200HX 93, Sungrow SG250HX 1096-1122, Sungrow SG250HX 11, Sungrow SG250HX 1616, Sungrow SG250HX 200-211, Sungrow SG250HX 248-255, Sungrow SG250HX 30-34, Sungrow SG250HX 300-322, Sungrow SG250HX 324-328, Sungrow SG250HX 38, Sungrow SG250HX 40-42, Sungrow SG250HX 401-412, Sungrow SG250HX 600-603, Sungrow SG250HX 605, Sungrow SG250HX 608, Sungrow SG250HX 612, Sungrow SG250HX 616, Sungrow SG250HX 620, Sungrow SG250HX 622-624, Sungrow SG250HX 76, Sungrow SG250HX 800, Sungrow SG250HX 802, Sungrow SG250HX 804, Sungrow SG250HX 807, Sungrow SG350HX 100-105, Sungrow SG350HX 107-114, Sungrow SG350HX 011, Sungrow SG350HX 116-124, Sungrow SG350HX 1616, Sungrow SG350HX 19-25, Sungrow SG350HX 200-211, Sungrow SG350HX 248-255, Sungrow SG350HX 030-034, Sungrow SG350HX 300-322, Sungrow SG350HX 324-328, Sungrow SG350HX 038, Sungrow SG350HX 040-042, Sungrow SG350HX 44-50, Sungrow SG350HX 52-58, Sungrow SG350HX 60-69, Sungrow SG350HX 85, Sungrow SG350HX 92, Sungrow SG350HX 93
Yaskawa Solectria
Yaskawa Solectria PVI-14-20TL IntFaultA~O, Yaskawa Solectria PVI-14-20TL IntProtectA~Z, Yaskawa Solectria PVI-25TL-R Protect0150, Yaskawa Solectria PVI-TL IntFault0010-150, Yaskawa Solectria PVI-TL IntProtect0010-0260, Yaskawa Solectria SGI-XTM Desat Error, Yaskawa Solectria XGI-1500-1MW CRIT-9, Yaskawa Solectria XGI-1500-1MW WARN-25, Yaskawa Solectria XGI-1500-1MW WARN-26, Yaskawa Solectria XGI-1500-1MW WARN-27, Yaskawa Solectria XGI-1500 CRIT-9, Yaskawa Solectria XGI-1500-DCG CRIT-9, Yaskawa Solectria XGI-1500-DCG WARN-25, Yaskawa Solectria XGI-1500-DCG WARN-26, Yaskawa Solectria XGI-1500-DCG WARN-27, Yaskawa Solectria XGI-1500 WARN-25, Yaskawa Solectria XGI-1500 WARN-26, Yaskawa Solectria XGI-1500 WARN-27

Claims

defined_in

c1 drafted · lead STPxx-US-50-BE-en-14

reports

c2 drafted · lead Internal device fault

affects

c3 drafted · lead Insulation monitoring device

c4 drafted · lead PV array

has_event_class

c5 drafted · lead Fault (device stops or needs intervention)

Implied by the inverter reconnecting to the grid afterward.

review note: support check: partial - Reconnecting to the grid implies a disconnect, but fault classification is not clearly stated; weakly implied.

has_production_effect

c6 drafted · lead Trip (production stops)

Implied by the reconnection to the grid.

has_recovery

c7 drafted · lead Auto-reset (clears by itself)

Single occurrences reconnect within minutes; if recurring, test insulation, isolate the faulty string, then replace the inverter.

review note: support check: partial - Single occurrences reconnect within minutes (auto-recovery implied), and the recurring steps are listed, though no explicit auto-reset wording.

detected_by

c8 drafted · lead Insulation resistance testing

c9 drafted · lead DC voltage measurement

review note: support check: partial - Voltage measurement is mentioned within faulty string tests, but as a follow-up step rather than detection.

mitigated_by

c10 drafted · lead String isolation

c11 drafted · lead DC wiring check

c12 drafted · lead Inverter replacement

When the event persists or recurs after the string is repaired.

applies_to

c13 drafted · lead Sunny Tripower X US-50

Data