Fault codes › SMA › Sunny Tripower X 13-30-US (STP xx-US-50)
SMA STP-X-US 6438
- Code
6438
- Shown as
- Self-diagnosis > Interference device
- Page
- 91
- ID
fc:sma-stp-x-us-50-6438
- IRI
https://solarlattice.org/kb/fc/sma-stp-x-us-50-6438
- Status
- active
- Also known as
- 6438, SMA 6438, Self-diagnosis > Interference device
- Category
- Inverters
Class
fault drafted · lead
Production
stops drafted · lead
Decoded
Reports internal device fault; look at inverter bridge, grid tie relay; confirm with grid voltage measurement; do: inverter restart, inverter replacement.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
- STPxx-US-50-BE-en-14 — SMA · page 91 drafted · lead
sec=11.1.34 h=13035cbe4ca6
sec=h535 h=75f49e9e17fb
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E012, ABB / FIMER PVS-166-175-TL E024, ABB / FIMER PVS-166-175-TL E034, ABB / FIMER PVS-166-175-TL E049, ABB / FIMER PVS-166-175-TL E009, ABB / FIMER PVS-60-TL E012, ABB / FIMER PVS-60-TL E024, ABB / FIMER PVS-60-TL E034, ABB / FIMER PVS-60-TL E049, ABB / FIMER PVS-60-TL E081, ABB / FIMER PVS-60-TL E009, ABB / FIMER TRIO-20.0-27.6-TL E012, ABB / FIMER TRIO-20.0-27.6-TL E024, ABB / FIMER TRIO-20.0-27.6-TL E034, ABB / FIMER TRIO-20.0-27.6-TL E049, ABB / FIMER TRIO-20.0-27.6-TL E009, ABB / FIMER UNO-DM-3.3-5.0-PLUS E012, ABB / FIMER UNO-DM-3.3-5.0-PLUS E024, ABB / FIMER UNO-DM-3.3-5.0-PLUS E034, ABB / FIMER UNO-DM-3.3-5.0-PLUS E049, ABB / FIMER UNO-DM-3.3-5.0-PLUS E081, ABB / FIMER UNO-DM-3.3-5.0-PLUS E009, ABB / FIMER UNO-DM-6.0-PLUS E012, ABB / FIMER UNO-DM-6.0-PLUS E024, ABB / FIMER UNO-DM-6.0-PLUS E034, ABB / FIMER UNO-DM-6.0-PLUS E049, ABB / FIMER UNO-DM-6.0-PLUS E081, ABB / FIMER UNO-DM-6.0-PLUS E009
- CPS
- CPS SCA25KTL-208 Fault0060, CPS SCA25KTL-208 Protect0150, CPS SCA25KTL-480 Fault0060, CPS SCA25KTL-480 Protect0150, CPS SCA36KTL EepromErr, CPS SCA36KTL Fault0060, CPS SCA36KTL Protect0100, CPS SCA36KTL Protect0150, CPS SCA36KTL Protect0180, CPS SCA50-100K-T PFault0010, CPS SCA50-100K-T PFault0130, CPS SCA50-100K-T PFault0070, CPS SCA50-100K-T Protect1050, CPS SCA50-100K-T Protect0150, CPS SCA50-100K-T Protect0330, CPS SCA50-100K-T Protect0730, CPS SCA50-100K-T Protect0740, CPS SCA50-60KTL EepromErr, CPS SCA50-60KTL Fault0060, CPS SCA50-60KTL Protect0100, CPS SCA50-60KTL Protect0150, CPS SCA50-60KTL Protect0180, CPS SCH100-125KTL Fault0060, CPS SCH100-125KTL Protect0150, CPS SCH125KTL-AIO Fault0060, CPS SCH125KTL-AIO Protect0150, CPS SCH200-250K-T Fault0740, CPS SCH275KTL Fault0060, CPS SCH275KTL Protect0150, CPS SCH350KTL Fault0060, CPS SCH350KTL Protect0150
- Canadian Solar
- Canadian Solar 125K-T600GL02 IN I-PRO, Canadian Solar 125KTL-GS-E IN I-PRO, Canadian Solar 185-255K INI-FAULT, Canadian Solar 23-28KTL-CT IntFault0010-0150, Canadian Solar 23-28KTL-CT IntProtect0010-0620, Canadian Solar 25-40K-T480GL01 INI-FAULT, Canadian Solar 25-40KTL-GS-FL IN I-PRO, Canadian Solar 50-66K-T480GL01 INI-FAULT, Canadian Solar 50-66KTL-GS-FL IN I-PRO, Canadian Solar 75-100K-T480GL02 INI-FAULT
- Fronius
- Fronius Primo 426-428, Fronius Primo 431, Fronius Symo 426-428, Fronius Symo 431, Fronius Symo 518, Fronius Symo 760
- Huawei
- Huawei SUN2000-100KTL-USH0 2064, Huawei SUN2000-25-30KTL-US 400, Huawei SUN2000-25-30KTL-US 410, Huawei SUN2000-45KTL-US-HV-D0 400, Huawei SUN2000-45KTL-US-HV-D0 410
- KACO new energy
- KACO new energy blueplanet TL3 31
- SMA
- SMA SBSE-US-50 6001-6499, SMA SBSE-US-50 6606, SMA SBSE-US-50 6633, SMA SBSE-US-50 7702, SMA SBSE-US-50 7703, SMA SBSE-US-50 9107, SMA PEAK3-US 6001-6499, SMA PEAK3-US 6438, SMA PEAK3-US 7701, SMA PEAK3-US 9107, SMA CORE1-US 6002-6412, SMA CORE1-US 6107, SMA CORE1-US 7702, SMA STP-TL-US 6001-6438, SMA STP-TL-US 6606, SMA STP-TL-US 7701-7703, SMA STP-X-US 6001-6499, SMA STP-X-US 6101, SMA STP-X-US 6107, SMA STP-X-US 6202, SMA STP-X-US 6401, SMA STP-X-US 6422, SMA STP-X-US 7702, SMA STP-X-US 7703, SMA SC-CP-XT 6115, SMA SC-CP-XT 6117, SMA SC-CP-XT 6120, SMA SC-CP-XT 6121, SMA SC-CP-XT 6122, SMA SC-CP-XT 6422, SMA SC-CP-XT 6443, SMA SC-CP-XT 7601, SMA SI-US F781, SMA SI-US W713
- Schneider Electric
- Schneider Electric CL125 041, Schneider Electric CL125 044, Schneider Electric CL125 048, Schneider Electric CL125 049, Schneider Electric CL125 050, Schneider Electric CL125 060
- Solis
- Solis 1P-4G-US INI-FAULT, Solis 3P-5G-US INI-FAULT, Solis RHI-1P-HV INI-FAULT, Solis S5-GC INI-FAULT, Solis S6-EH1P INI-FAULT, Solis S6-EH2P INI-FAULT, Solis S6-EH3P30-60K INI-FAULT, Solis S6-EH3P75-150K INI-FAULT, Solis S6-GC INI-FAULT, Solis S6-GC PID Repairing, Solis S6-GU INI-FAULT, Solis S6-GU PID Repairing
- Sungrow
- Sungrow SG-CX-US 011, Sungrow SG-CX-US 116-117, Sungrow SG-CX-US 019-020, Sungrow SG-CX-US 021-022, Sungrow SG-CX-US 024-025, Sungrow SG-CX-US 030-034, Sungrow SG-CX-US 038, Sungrow SG-CX-US 040-042, Sungrow SG-CX-US 044-046, Sungrow SG-CX-US 048-050, Sungrow SG-CX-US 053-056, Sungrow SG-CX-US 059-060, Sungrow SG-CX-US 076, Sungrow SG200HX 100-105, Sungrow SG200HX 107-114, Sungrow SG200HX 011, Sungrow SG200HX 116-124, Sungrow SG200HX 1616, Sungrow SG200HX 19-25, Sungrow SG200HX 200-211, Sungrow SG200HX 248-255, Sungrow SG200HX 030-034, Sungrow SG200HX 300-322, Sungrow SG200HX 324-328, Sungrow SG200HX 038, Sungrow SG200HX 040-042, Sungrow SG200HX 44-50, Sungrow SG200HX 52-58, Sungrow SG200HX 60-69, Sungrow SG200HX 85, Sungrow SG200HX 92, Sungrow SG200HX 93, Sungrow SG250HX 1096-1122, Sungrow SG250HX 11, Sungrow SG250HX 1616, Sungrow SG250HX 200-211, Sungrow SG250HX 248-255, Sungrow SG250HX 30-34, Sungrow SG250HX 300-322, Sungrow SG250HX 324-328, Sungrow SG250HX 38, Sungrow SG250HX 40-42, Sungrow SG250HX 401-412, Sungrow SG250HX 600-603, Sungrow SG250HX 605, Sungrow SG250HX 608, Sungrow SG250HX 612, Sungrow SG250HX 616, Sungrow SG250HX 620, Sungrow SG250HX 622-624, Sungrow SG250HX 76, Sungrow SG250HX 800, Sungrow SG250HX 802, Sungrow SG250HX 804, Sungrow SG250HX 807, Sungrow SG350HX 100-105, Sungrow SG350HX 107-114, Sungrow SG350HX 011, Sungrow SG350HX 116-124, Sungrow SG350HX 1616, Sungrow SG350HX 19-25, Sungrow SG350HX 200-211, Sungrow SG350HX 248-255, Sungrow SG350HX 030-034, Sungrow SG350HX 300-322, Sungrow SG350HX 324-328, Sungrow SG350HX 038, Sungrow SG350HX 040-042, Sungrow SG350HX 44-50, Sungrow SG350HX 52-58, Sungrow SG350HX 60-69, Sungrow SG350HX 85, Sungrow SG350HX 92, Sungrow SG350HX 93
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL IntFaultA~O, Yaskawa Solectria PVI-14-20TL IntProtectA~Z, Yaskawa Solectria PVI-25TL-R Protect0150, Yaskawa Solectria PVI-TL IntFault0010-150, Yaskawa Solectria PVI-TL IntProtect0010-0260, Yaskawa Solectria SGI-XTM Desat Error, Yaskawa Solectria XGI-1500-1MW CRIT-9, Yaskawa Solectria XGI-1500-1MW WARN-25, Yaskawa Solectria XGI-1500-1MW WARN-26, Yaskawa Solectria XGI-1500-1MW WARN-27, Yaskawa Solectria XGI-1500 CRIT-9, Yaskawa Solectria XGI-1500-DCG CRIT-9, Yaskawa Solectria XGI-1500-DCG WARN-25, Yaskawa Solectria XGI-1500-DCG WARN-26, Yaskawa Solectria XGI-1500-DCG WARN-27, Yaskawa Solectria XGI-1500 WARN-25, Yaskawa Solectria XGI-1500 WARN-26, Yaskawa Solectria XGI-1500 WARN-27
Same code in other families
Claims
defined_in
c1 drafted · lead
STPxx-US-50-BE-en-14
reports
c2 drafted · lead
Internal device fault
Operating conditions for the internal AC converter stage were not met.
affects
c3 drafted · lead
Inverter bridge
c4 drafted · lead
Grid tie relay
has_event_class
c5 drafted · lead
Fault (device stops or needs intervention)
has_production_effect
c6 drafted · lead
Trip (production stops)
has_recovery
c7 drafted · lead
Manual reset (operator restarts or acknowledges)
Applies when the event is frequent or permanent: disconnect and recommission; replace the inverter if it persists.
review note: support check: partial - Disconnect and recommission is an operator action implying manual reset, but not explicitly stated as clearing.
detected_by
c8 drafted · lead
Grid voltage measurement
review note: support check: partial - Mains voltage check is a corrective measure rather than a detection method.
mitigated_by
c9 drafted · lead
Inverter restart
review note: support check: partial - The corrective measures amount to disconnecting, waiting for LEDs to go out and recommissioning, which is roughly a restart, but…
c10 drafted · lead
Inverter replacement
When the event persists or the relays do not switch.
applies_to
c11 drafted · lead
Sunny Tripower X US-50