String isolation
String isolation means taking the affected string out of service before further diagnosis or repair work on a suspect module. It is the first step of the corrective action for a module hotspot from cell damage. After isolating the string, the thermal signature is checked under load, the module is replaced if cell damage is confirmed, and the string current is retested after the repair. For junction box failure, safety isolation should be the priority when there is evidence of arcing or burning. This priority matters because bad wiring or poor solder contacts in a junction box can cause internal arcing or heating that may start a fire. One thermal anomaly does not prove the module is permanently damaged, so confirm the electrical impact and that the anomaly repeats before approving a replacement. Raise the priority when the anomaly stays stable across inspections or when several modules in the same string show related signatures.
<!-- review notes
- sentence 1: support check: partial - The passages list 'Isolate the string' as a mitigation step but never define it as taking the string out of service before further diagnosis or repair (verification under load follows isolation). -->
Referenced by
- Canadian Solar 185-255K DC-INTF
mitigated_byc6 - Canadian Solar 185-255K OV-DCA-I
mitigated_byc6 - CPS SCA25KTL-208 Fault0090
mitigated_byc7 - CPS SCA25KTL-208 PVxReverse
mitigated_byc6 - CPS SCA25KTL-480 Fault0090
mitigated_byc7 - CPS SCA50-100K-T Fault2000-2150
mitigated_byc6 - CPS SCA50-100K-T Fault3000-3070
mitigated_byc6 - CPS SCH100-125KTL Fault0090
mitigated_byc7 - CPS SCH125KTL-AIO Fault0090
mitigated_byc7 - CPS SCH275KTL Fault0090
mitigated_byc7 - CPS SCH350KTL CfLowErr
mitigated_byc5 - CPS SCH350KTL Fault0090
mitigated_byc7 - SMA STP-X-US 6401
mitigated_byc10 - Solis 3P-5G-US DC-INTF
mitigated_byc7 - Solis 3P-5G-US OV-DCA-I
mitigated_byc5 - Solis RHI-1P-HV DC-INTF
mitigated_byc7 - Solis RHI-1P-HV OV-DCA-I
mitigated_byc5 - Solis S6-EH1P DC-INTF
mitigated_byc7 - Solis S6-EH1P OV-DCA-I
mitigated_byc5 - Solis S6-EH2P DC-INTF
mitigated_byc7 - Solis S6-EH2P OV-DCA-I
mitigated_byc5 - Solis S6-EH3P30-60K DC-INTF
mitigated_byc8 - Solis S6-EH3P30-60K OV-DCA-I
mitigated_byc6 - Solis S6-EH3P75-150K DC-INTF
mitigated_byc7 - Solis S6-EH3P75-150K OV-DCA-I
mitigated_byc5 - Solis S6-GC DC-INTF
mitigated_byc7 - Solis S6-GC OV-DCA-I
mitigated_byc5 - Solis S6-GU DC-INTF
mitigated_byc7 - Solis S6-GU OV-DCA-I
mitigated_byc5 - Sungrow SG200HX 1600-1615
mitigated_byc5 - Sungrow SG200HX 1632-1655
mitigated_byc5 - Sungrow SG250HX 1600-1615
mitigated_byc5 - Sungrow SG250HX 1632-1655
mitigated_byc5 - Sungrow SG350HX 1600-1615
mitigated_byc5 - Sungrow SG350HX 1632-1655
mitigated_byc5 - Junction Box Failure
mitigated_byc37 - Module Hotspot from Cell Damage
mitigated_byc13