Fault codes › SMA › Sunny Tripower 12000-30000TL-US (STP xxxxxTL-US-10)

SMA STP-TL-US 3302

Code
3302
Shown as
Unstable operation > Abort self-test
Page
48
ID
fc:sma-stp-tl-us-3302
IRI
https://solarlattice.org/kb/fc/sma-stp-tl-us-3302
Status
active
Also known as
3302, SMA 3302, Unstable operation > Abort self-test
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears by itself drafted · lead

Decoded

Reports insufficient DC input power, insufficient solar irradiance; look at PV array; do: string configuration correction.

What can be behind Insufficient DC input power

Failure modes that present as the reported condition, and the tests that tell them apart.

What can be behind Insufficient solar irradiance

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E017, ABB / FIMER PVS-166-175-TL W001, ABB / FIMER PVS-166-175-TL W002, ABB / FIMER PVS-60-TL E017, ABB / FIMER PVS-60-TL W001, ABB / FIMER PVS-60-TL W002, ABB / FIMER TRIO-20.0-27.6-TL E017, ABB / FIMER TRIO-20.0-27.6-TL W001, ABB / FIMER TRIO-20.0-27.6-TL W002, ABB / FIMER UNO-DM-3.3-5.0-PLUS E017, ABB / FIMER UNO-DM-3.3-5.0-PLUS W001, ABB / FIMER UNO-DM-3.3-5.0-PLUS W002, ABB / FIMER UNO-DM-6.0-PLUS E017, ABB / FIMER UNO-DM-6.0-PLUS W001, ABB / FIMER UNO-DM-6.0-PLUS W002
Fronius
Fronius Galvo 306, Fronius Symo 306
SMA
SMA SB-US-40 3301-3303, SMA SB-US-40 3901-3902, SMA SB-US-40 9005, SMA SB-US-41 3301, SMA SB-US-41 3303, SMA SB-US-41 3901, SMA SB-US-41 3902, SMA SB-US-41 9005, SMA SBSE-US-50 29254, SMA SBSE-US-50 3302, SMA SBSE-US-50 3303, SMA SBSE-US-50 3901, SMA SBSE-US-50 3902, SMA CORE1-US 9005, SMA STP-TL-US 3301, SMA STP-TL-US 3303, SMA STP-TL-US 3901-3902, SMA STP-TL-US 9005, SMA STP-X-US 3901, SMA STP-X-US 3902
Schneider Electric
Schneider Electric CL125 075
Yaskawa Solectria
Yaskawa Solectria SGI-XTM DC Volt Low, Yaskawa Solectria SGI-XTM Low DC Power

Same code in other families

Claims

defined_in

c1 drafted · lead STPTL-US-10-IA-xx-22

reports

c2 verified · fact Insufficient DC input power

verified by: review-workflowverified on: 2026-10-23

c3 drafted · lead Insufficient solar irradiance

affects

c4 drafted · lead PV array

has_event_class

c5 drafted · lead Fault (device stops or needs intervention)

review note: support check: partial - Feed-in is interrupted, but fault versus warning is not stated.

has_production_effect

c6 drafted · lead Trip (production stops)

has_recovery

c7 drafted · lead Auto-reset (clears by itself)

Resumes when irradiation rises; if frequent, check array sizing and wiring

review note: support check: partial - Waiting for irradiation to increase implies auto-resume but is not explicit.

mitigated_by

c8 drafted · lead String configuration correction

Only when the message recurs frequently

applies_to

c9 drafted · lead Sunny Tripower TL-US

Data