Solar Lattice

Fault codes › SMA › Sunny Tripower X 13-30-US (STP xx-US-50)

SMA STP-X-US 6404

Code
6404
Shown as
Self-diagnosis > Interference device
Page
90
ID
fc:sma-stp-x-us-50-6404
IRI
https://solarlattice.org/kb/fc/sma-stp-x-us-50-6404
Status
active
Also known as
6404, SMA 6404, Self-diagnosis > Interference device
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears by itself drafted · lead

Decoded

Reports AC overcurrent; do: inverter replacement, contact manufacturer service.

What can be behind AC overcurrent

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

ABB / FIMER
ABB / FIMER PVS-166-175-TL E006, ABB / FIMER PVS-60-TL E006, ABB / FIMER TRIO-20.0-27.6-TL E006, ABB / FIMER UNO-DM-3.3-5.0-PLUS E006, ABB / FIMER UNO-DM-6.0-PLUS E006
CPS
CPS SCA50-100K-T Protect1110
Canadian Solar
Canadian Solar 185-255K OV-G-I
Fronius
Fronius Galvo 301, Fronius Primo 301, Fronius Symo 301
Huawei
Huawei SUN2000-100KTL-USH0 2039, Huawei SUN2000-25-30KTL-US 202, Huawei SUN2000-45KTL-US-HV-D0 202
KACO new energy
KACO new energy blueplanet TL3 36, KACO new energy blueplanet TL3 87, KACO new energy blueplanet TL3 88, KACO new energy blueplanet TL3 89
SMA
SMA SC-CP-XT 6404, SMA SI-US F117, SMA SI-US W118, SMA SI-US W119, SMA SI-US W120, SMA SI-US W377, SMA SI-US W378, SMA SI-US W379, SMA SI-US W380, SMA SI-US W505, SMA SI-US W506, SMA SI-US W507, SMA SI-US W508
Schneider Electric
Schneider Electric CL125 040, Schneider Electric CL125 006, Schneider Electric CL125 007
Solis
Solis 1P-4G-US GRID-INTF, Solis 3P-5G-US OV-G-I, Solis RHI-1P-HV OV-G-I, Solis RHI-1P-HV OV-IgTr, Solis S5-GC GRID-INTF, Solis S6-EH1P OV-G-I, Solis S6-EH1P OV-IgTr, Solis S6-EH2P GRID-INTF, Solis S6-EH2P OV-G-I, Solis S6-EH3P30-60K GRID-INTF, Solis S6-EH3P30-60K OV-G-I, Solis S6-EH3P75-150K GRID-INTF, Solis S6-EH3P75-150K OV-G-I, Solis S6-GC GRID-INTF, Solis S6-GC OV-G-I, Solis S6-GC OV-IgTr, Solis S6-GU GRID-INTF, Solis S6-GU OV-G-I, Solis S6-GU OV-IgTr
Sungrow
Sungrow SG-CX-US 007, Sungrow SG200HX 007, Sungrow SG250HX 7, Sungrow SG350HX 007

Same code in other families

Claims

defined_in

c1 drafted · lead STPxx-US-50-BE-en-14

reports

c2 drafted · lead AC overcurrent

has_event_class

c3 drafted · lead Fault (device stops or needs intervention)

review note: support check: partial - The inverter disconnects from the grid, which implies a fault, but the passage doesn't explicitly classify it as a fault.

has_production_effect

c4 drafted · lead Trip (production stops)

has_recovery

c5 drafted · lead Auto-reset (clears by itself)

Occasional occurrence needs no action; permanent presence requires assembly or inverter replacement.

review note: support check: partial - Occasional occurrence needing no action is stated, but auto-reset is not explicitly stated.

mitigated_by

c6 drafted · lead Inverter replacement

When the event is permanently present.

c7 drafted · lead Contact manufacturer service

applies_to

c8 drafted · lead Sunny Tripower X US-50

Data