Fault codes › Solis › Solis-1P(3.6-10)K-4G-US
Solis 1P-4G-US GRID-INTF
- Code
GRID-INTF
- Shown as
- Grid unstable
- Page
- 62
- ID
fc:solis-1p-4g-us-gridintf
- IRI
https://solarlattice.org/kb/fc/solis-1p-4g-us-gridintf
- Status
- active
- Also known as
- GRID-INTF, gridintf, Solis GRID-INTF, Grid unstable
- Category
- Inverters
Class
not stated
Production
not stated
Clears
not stated
Decoded
Reports grid instability, AC overcurrent; confirm with grid voltage measurement, waveform spectrum analysis; do: grid impedance matching, inverter restart.
Failure modes that present as the reported condition, and the tests that tell them apart.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E006, ABB / FIMER PVS-166-175-TL W003, ABB / FIMER PVS-60-TL E006, ABB / FIMER PVS-60-TL W003, ABB / FIMER TRIO-20.0-27.6-TL E006, ABB / FIMER TRIO-20.0-27.6-TL W003, ABB / FIMER UNO-DM-3.3-5.0-PLUS E006, ABB / FIMER UNO-DM-3.3-5.0-PLUS W003, ABB / FIMER UNO-DM-6.0-PLUS E006, ABB / FIMER UNO-DM-6.0-PLUS W003
- CPS
- CPS SCA50-100K-T Protect1110
- Canadian Solar
- Canadian Solar 125K-T600GL02 GRID-INTF, Canadian Solar 125KTL-GS-E GRID-INTF, Canadian Solar 185-255K GRID-INTF01/02, Canadian Solar 185-255K OV-G-I, Canadian Solar 25-40K-T480GL01 GRID-INTF, Canadian Solar 25-40KTL-GS-FL GRID-INTF, Canadian Solar 50-66K-T480GL01 GRID-INTF, Canadian Solar 50-66KTL-GS-FL GRID-INTF, Canadian Solar 75-100K-T480GL02 GRID-INTF
- Fronius
- Fronius Galvo 301, Fronius Primo 301, Fronius Symo 301
- Huawei
- Huawei SUN2000-100KTL-USH0 2038, Huawei SUN2000-100KTL-USH0 2039, Huawei SUN2000-25-30KTL-US 202, Huawei SUN2000-45KTL-US-HV-D0 202
- KACO new energy
- KACO new energy blueplanet TL3 36, KACO new energy blueplanet TL3 87, KACO new energy blueplanet TL3 88, KACO new energy blueplanet TL3 89
- SMA
- SMA SB-US-41 404, SMA SBSE-US-50 404, SMA STP-TL-US 404, SMA STP-X-US 404, SMA STP-X-US 6404, SMA SC-CP-XT 404, SMA SC-CP-XT 6404, SMA SI-US F117, SMA SI-US W118, SMA SI-US W119, SMA SI-US W120, SMA SI-US W377, SMA SI-US W378, SMA SI-US W379, SMA SI-US W380, SMA SI-US W505, SMA SI-US W506, SMA SI-US W507, SMA SI-US W508
- Schneider Electric
- Schneider Electric CL125 040, Schneider Electric CL125 006, Schneider Electric CL125 007
- Solis
- Solis 3P-5G-US GRID-INTF01/02, Solis 3P-5G-US OV-G-I, Solis RHI-1P-HV GRID-INTF01/02, Solis RHI-1P-HV OV-G-I, Solis RHI-1P-HV OV-IgTr, Solis S5-GC GRID-INTF, Solis S6-EH1P GRID-INTF01/02, Solis S6-EH1P OV-G-I, Solis S6-EH1P OV-IgTr, Solis S6-EH2P G-F-GLU, Solis S6-EH2P GRID-INTF, Solis S6-EH2P GRID-INTF02, Solis S6-EH2P OV-G-I, Solis S6-EH3P30-60K G-F-GLU, Solis S6-EH3P30-60K GRID-INTF, Solis S6-EH3P30-60K GRID-INTF02, Solis S6-EH3P30-60K OV-G-I, Solis S6-EH3P75-150K G-F-GLU, Solis S6-EH3P75-150K GRID-INTF, Solis S6-EH3P75-150K GRID-INTF02, Solis S6-EH3P75-150K OV-G-I, Solis S6-GC GRID-INTF, Solis S6-GC OV-G-I, Solis S6-GC OV-IgTr, Solis S6-GU GRID-INTF, Solis S6-GU OV-G-I, Solis S6-GU OV-IgTr
- Sungrow
- Sungrow SG-CX-US 007, Sungrow SG200HX 007, Sungrow SG250HX 7, Sungrow SG350HX 007
Same code in other families
Claims
defined_in
c1 drafted · lead
Solis_Manual_Solis-1P(6-10)K-4G-US_PLUS_V2.1_20250804
c2 drafted · lead
Solis_Manual_(3.6-5)K_4G_PLUS_LW_USA_03212023
reports
c3 drafted · lead
Grid instability
c4 drafted · lead
AC overcurrent
detected_by
c5 drafted · lead
Grid voltage measurement
c6 drafted · lead
Waveform spectrum analysis
Harmonic distortion test of the AC line.
mitigated_by
c7 drafted · lead
Grid impedance matching
c8 drafted · lead
Inverter restart
applies_to
c9 drafted · lead
Solis-1P(3.6-10)K-4G-US
Data