Solis-1P(3.6-10)K-4G-US

ID
prod:solis-1p-4g-us
IRI
https://solarlattice.org/kb/prod/solis-1p-4g-us
Status
active
Also known as
Solis-1P3.6K-4G-US, Solis-1P5K-4G-US, Solis-1P6K-4G-US, Solis-1P7.6K-4G-US, Solis-1P10K-4G-US, 4G Series Grid Inverter
Category
Inverters
Make
solis
Product level
family

The Solis-1P 4G-US is a family of single-phase grid-tied inverters made by Solis, with models from 3.6K to 10K. The 6K, 7.6K and 10K models are rated at 6 kW, 7.6 kW and 10 kW of output, accept up to 600 V DC input and run on a 60 Hz grid. CEC efficiency is 96.6% on the 3.6K, 97.1% on the 5K and 97.5% on the 6K through 10K models. The 7.6K and 10K models use a transformerless topology and have an LCD display. RS-485 is the standard communication interface, and cellular or Wi-Fi are available as options. The inverter has DC arc-fault protection. An AFCI Check FAULT alarm means the AFCI module failed its self-check. To clear it, reset the inverter by switching the DC off and back on, and replace the inverter if the fault returns.

<!-- review notes

Claims

manufactured_by

c1 verified · fact Solis

verified by: review-workflowverified on: 2026-10-24review note: support check: partial - Manuals cover the model but the passages never name Solis as the maker explicitly beyond the title/model name.

implements

c2 drafted · lead DC arc-fault protection

The manual has an ARC Fault section, and the inverter self-checks its AFCI module.

review note: support check: partial - ARC Fault section and AFCI self-check fault imply AFCI, but protection is not explicitly stated.

uses_protocol

c3 drafted · lead RS-485

Conditions: Standard on the 6K and 10K models

c4 drafted · lead Cellular data

Conditions: Optional on the 6K and 10K models

c5 drafted · lead Wi-Fi

Conditions: Optional on the 6K and 10K models

certified_to

c6 drafted · lead UL 1741 SB proposed

Conditions: Listed for the 6K, 7.6K and 10K models

c7 drafted · lead UL 1741 SA proposed

Conditions: Listed for the 6K, 7.6K and 10K models

c8 drafted · lead IEEE 1547-2018 proposed

Conditions: Listed for the 6K, 7.6K and 10K models

c9 drafted · lead UL 1699B proposed

Conditions: Listed for the 6K, 7.6K and 10K models

c10 verified · fact UL 1998 proposed

Conditions: Listed for the 6K, 7.6K and 10K models

verified by: review-workflowverified on: 2026-10-24

c11 drafted · lead FCC Part 15 proposed

Conditions: Class B; listed for the 6K, 7.6K and 10K models

c12 drafted · lead CA Rule 21 proposed

Conditions: Listed for the 6K, 7.6K and 10K models

c13 drafted · lead Hawaiian Electric Rule 14H proposed

Conditions: Listed for the 6K, 7.6K and 10K models

c14 drafted · lead NEC 2020 690.12 Rapid shutdown of PV systems on buildings proposed

Conditions: Listed for the 6K, 7.6K and 10K models

rated_power

c15 drafted · lead nominal 6 KiloW

Conditions: Solis-1P6K-4G-US rated output power

review note: possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions)

c16 verified · fact nominal 7.6 KiloW

Conditions: Solis-1P7.6K-4G-US rated output power

verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c15 (same source; check the conditions); possible conflict with c17 (same source; check the conditions)

c17 verified · fact nominal 10 KiloW

Conditions: Solis-1P10K-4G-US rated output power

verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions)

max_input_voltage

c18 drafted · lead ≤ 600 V

Conditions: Solis-1P6K, 7.6K and 10K-4G-US models

frequency

c19 drafted · lead nominal 60 HZ

Conditions: Grid frequency, 6K, 7.6K and 10K models

c20 drafted · lead 59.5–60.5 HZ

Conditions: Grid frequency range, Solis-1P10K-4G-US

efficiency

c21 disputed nominal 96.6 PERCENT

Conditions: CEC efficiency, Solis-1P3.6K-4G-US

review note: possible conflict with c22 (same source; check the conditions)conflicts with: Solis-1P(3.6-10)K-4G-US (c23)

c22 disputed nominal 97.1 PERCENT

Conditions: CEC efficiency, Solis-1P5K-4G-US

review note: possible conflict with c21 (same source; check the conditions)conflicts with: Solis-1P(3.6-10)K-4G-US (c23)

c23 disputed nominal 97.5 PERCENT

Conditions: CEC efficiency, Solis-1P6K, 7.6K and 10K-4G-US

conflicts with: Solis-1P(3.6-10)K-4G-US (c21)conflicts with: Solis-1P(3.6-10)K-4G-US (c22)

Referenced by

Data