Waveform spectrum analysis
Waveform spectrum analysis looks at the frequency content of a PV system's current and voltage waveforms. It is one of the current ways to identify DC arc faults. A DC arc fault is a sudden high-power discharge between two conductors. It can occur in series between neighbouring conductors in a string, or in parallel between strings, and it often causes destructive fires. Arcs are transient by nature, so they are hard to catch. Analysing the waveforms is one way to find them. Power quality meters with an oscilloscope-like tool can capture voltage and current waveforms. They show both the time trace and the frequency spectrum, in magnitude, percent or dB. On one such tool, you sample at 128 or 512 samples per cycle and record for 2 to 60 cycles. You need at least 12 cycles to get 5 Hz bin resolution. Captured waveforms can be exported to CSV and imported again later for review. A signal that points to a fault under some conditions can be normal under others, such as clouds instead of full sun. Compare a suspect signature with past behaviour under similar conditions. Detection alone does not protect the system. Arc fault circuit interrupters installed on individual strings provide the protection against arc faults.
<!-- review notes
- sentence 2: support check: partial - Sudden high-power discharge, series/parallel occurrence and destructive fires are stated, but 'usually causing' fires is fair while 'between strings' and 'neighbouring conductors' match; minor softening is fine, though 'often' vs 'usually' is the only drift, so core is supported yet slightly weaker.
- sentence 3: support check: partial - Transient nature and difficult detection are stated, and waveform spectrum analysis is listed as a method, but 'analysing the waveforms' is a looser paraphrase of spectrum analysis.
- sentence 8: support check: partial - Passage says AFCIs on individual strings can protect against arc faults, but does not say detection alone is insufficient or that AFCIs are the protection. -->
Referenced by
- Harmonic distortion
related_toc1 - Series and parallel arc faults
related_toc7 - Canadian Solar 125K-T600GL02 GRID-INTF
detected_byc3 - Canadian Solar 125KTL-GS-E GRID-INTF
detected_byc3 - Canadian Solar 25-40K-T480GL01 GRID-INTF
detected_byc3 - Canadian Solar 25-40KTL-GS-FL GRID-INTF
detected_byc3 - Canadian Solar 50-66K-T480GL01 GRID-INTF
detected_byc3 - Canadian Solar 50-66KTL-GS-FL GRID-INTF
detected_byc3 - Canadian Solar 75-100K-T480GL02 GRID-INTF
detected_byc3 - Solis 1P-4G-US GRID-INTF
detected_byc6 - Solis S5-GC GRID-INTF
detected_byc5 - Solis S6-EH2P GRID-INTF
detected_byc5 - Solis S6-EH2P GRID-INTF02
detected_byc4 - Solis S6-EH3P30-60K GRID-INTF
detected_byc6 - Solis S6-EH3P30-60K GRID-INTF02
detected_byc5 - Solis S6-EH3P75-150K GRID-INTF
detected_byc5 - Solis S6-EH3P75-150K GRID-INTF02
detected_byc4 - Solis S6-GC GRID-INTF
detected_byc6 - Solis S6-GU GRID-INTF
detected_byc5 - Arc fault
detected_byc11