Battery deep discharge protection

ID
symptom:battery-deep-discharge
IRI
https://solarlattice.org/kb/symptom/battery-deep-discharge
Status
active
Also known as
Deep discharge protection activated, Battery fault, BatRes

On SMA battery inverters, event 9394 is logged when the battery management system turns on deep discharge protection. For grid-connected systems this message is only an event and not a warning. A related battery fault message means the battery has reached either the deep discharge protection area or the deep discharge area, and a fuse at the grid-connection point may have tripped. Inside the deep discharge protection range, the system switches to energy-saving mode and tries to recharge the battery automatically from available PV energy. The protection ranges are set as a percentage of battery capacity, and the allowed limits differ between lead-acid and lithium-ion batteries. Check first whether a fuse has tripped at the grid-connection point and whether PV energy is available to recharge the battery. Then review the deep discharge range settings for the battery type.

<!-- review notes

Claims

observed_as

c1 verified · fact Deep discharge event message

Event 9394 'Deep discharge protection activated' is logged when the battery management system enables deep discharge protection; on grid-connected systems it is an event, not a warning.

The battery management system has activated the deep discharge protection.

verified by: review-workflowverified on: 2026-10-23

c2 verified · fact Inverter fault code display

A related SMA 'Battery fault' message appears when the deep discharge protection area or deep discharge area is reached; a fuse at the grid-connection point may have tripped.

verified by: review-workflowverified on: 2026-10-23

Referenced by

Data