Symptom
Battery deep discharge protection
- ID
symptom:battery-deep-discharge
- IRI
https://solarlattice.org/kb/symptom/battery-deep-discharge
- Status
- active
- Also known as
- Deep discharge protection activated, Battery fault, BatRes
On SMA battery inverters, event 9394 is logged when the battery management system turns on deep discharge protection. For grid-connected systems this message is only an event and not a warning. A related battery fault message means the battery has reached either the deep discharge protection area or the deep discharge area, and a fuse at the grid-connection point may have tripped. Inside the deep discharge protection range, the system switches to energy-saving mode and tries to recharge the battery automatically from available PV energy. The protection ranges are set as a percentage of battery capacity, and the allowed limits differ between lead-acid and lithium-ion batteries. Check first whether a fuse has tripped at the grid-connection point and whether PV energy is available to recharge the battery. Then review the deep discharge range settings for the battery type.
<!-- review notes
- sentence 6: support check: partial - The fuse and PV recharge facts appear, but the passages give no troubleshooting order or instruction to check them or review settings by battery type.
-->
Claims
observed_as
c1 verified · fact
Deep discharge event message
Event 9394 'Deep discharge protection activated' is logged when the battery management system enables deep discharge protection; on grid-connected systems it is an event, not a warning.
The battery management system has activated the deep discharge protection.
verified by: review-workflowverified on: 2026-10-23
c2 verified · fact
Inverter fault code display
A related SMA 'Battery fault' message appears when the deep discharge protection area or deep discharge area is reached; a fuse at the grid-connection point may have tripped.