Fault codes › CPS › CPS SCA100K-T-US-480 / SCA50K-T-US-208
CPS SCA50-100K-T Protect0000
- Code
Protect0000
- Shown as
- Bus Sum High
- Vendor severity
- Protection
- Page
- 130
- ID
fc:chint-sca-50-100k-t-protect0
- IRI
https://solarlattice.org/kb/fc/chint-sca-50-100k-t-protect0
- Status
- active
- Also known as
- Protect0000, protect0, CPS Protect0000, Bus Sum High
- Category
- Inverters
Class
fault drafted · lead
Production
not stated
Decoded
Reports DC bus overvoltage; confirm with DC voltage measurement; do: inverter restart, inverter replacement.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E029, ABB / FIMER PVS-166-175-TL E004, ABB / FIMER PVS-60-TL E029, ABB / FIMER PVS-60-TL E004, ABB / FIMER TRIO-20.0-27.6-TL E029, ABB / FIMER TRIO-20.0-27.6-TL E004, ABB / FIMER UNO-DM-3.3-5.0-PLUS E029, ABB / FIMER UNO-DM-3.3-5.0-PLUS E004, ABB / FIMER UNO-DM-6.0-PLUS E029, ABB / FIMER UNO-DM-6.0-PLUS E004
- CPS
- CPS SCA25KTL-208 Fault0130, CPS SCA25KTL-208 Fault0020, CPS SCA25KTL-208 Protect0110, CPS SCA25KTL-208 Protect0090, CPS SCA25KTL-480 Fault0130, CPS SCA25KTL-480 Fault0020, CPS SCA25KTL-480 Protect0110, CPS SCA25KTL-480 Protect0090, CPS SCA50-100K-T Fault7000, CPS SCA50-100K-T PFault0000, CPS SCA50-100K-T PFault0110, CPS SCA50-100K-T Protect0110, CPS SCA50-100K-T Protect0300, CPS SCA50-100K-T Protect0090, CPS SCH100-125KTL Fault0130, CPS SCH100-125KTL Fault0020, CPS SCH100-125KTL Protect0110, CPS SCH100-125KTL Protect0090, CPS SCH125KTL-AIO Fault0130, CPS SCH125KTL-AIO Fault0020, CPS SCH125KTL-AIO Protect0110, CPS SCH125KTL-AIO Protect0090, CPS SCH200-250K-T Fault0130, CPS SCH200-250K-T Fault0030, CPS SCH200-250K-T Protect0000, CPS SCH200-250K-T Protect0300, CPS SCH275KTL Fault0130, CPS SCH275KTL Fault0020, CPS SCH275KTL Protect0110, CPS SCH275KTL Protect0090, CPS SCH350KTL Fault0130, CPS SCH350KTL Fault0020, CPS SCH350KTL Protect0110, CPS SCH350KTL Protect0090
- Canadian Solar
- Canadian Solar 125K-T600GL02 OV-BUS, Canadian Solar 125KTL-GS-E OV-BUS, Canadian Solar 185-255K OV-BUS, Canadian Solar 25-40K-T480GL01 OV-BUS, Canadian Solar 25-40KTL-GS-FL OV-BUS, Canadian Solar 50-66K-T480GL01 OV-BUS, Canadian Solar 50-66KTL-GS-FL OV-BUS, Canadian Solar 75-100K-T480GL02 OV-BUS
- Fronius
- Fronius Galvo 308, Fronius Primo 489, Fronius Symo 308, Fronius Symo 489
- KACO new energy
- KACO new energy blueplanet TL3 216, KACO new energy blueplanet TL3 35, KACO new energy blueplanet TL3 85
- SMA
- SMA STP-X-US 6405, SMA SC-CP-XT 6405
- Schneider Electric
- Schneider Electric CL125 019, Schneider Electric CL125 020
- Solis
- Solis 1P-4G-US OV-BUS, Solis 3P-5G-US OV-BUS, Solis RHI-1P-HV OV-BUS, Solis S5-GC OV-BUS, Solis S6-EH1P OV-BUS, Solis S6-EH2P OV-BUS, Solis S6-EH2P OV-BUS-H, Solis S6-EH3P30-60K OV-BUS, Solis S6-EH3P30-60K OV-BUS-H, Solis S6-EH3P75-150K OV-BUS, Solis S6-EH3P75-150K OV-BUS-H, Solis S6-GC OV-BUS, Solis S6-GU OV-BUS
- Yaskawa Solectria
- Yaskawa Solectria PVI-25TL-R Fault0130, Yaskawa Solectria PVI-25TL-R Fault0020, Yaskawa Solectria PVI-25TL-R Protect0110, Yaskawa Solectria SGI-XTM DC Overshoot
Same code in other families
Claims
defined_in
c1 drafted · lead
CPS SCA100K-T-US-480 SCA50K-T-US-208 User Manual Rev 1.0
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the code prefix
reports
c3 drafted · lead
DC bus overvoltage
detected_by
c4 drafted · lead
DC voltage measurement
review note: support check: partial - The passage says to measure the DC voltage as a check, not that the fault is detected by that measurement.
mitigated_by
c5 drafted · lead
Inverter restart
c6 drafted · lead
Inverter replacement
Only if restart does not clear the fault.
has_recovery
c7 drafted · lead
Manual reset (operator restarts or acknowledges)
Power-cycle first; replace inverter or contact service if it persists.
applies_to
c8 drafted · lead
CPS SCA100K-T-US-480 / SCA50K-T-US-208
Data