Solar Lattice

Fault codes › CPS › CPS SCA50/60KTL-DO/US-480

CPS SCA50-60KTL Arcboard Err

Code
Arcboard Err
Vendor severity
Protection
Page
7
ID
fc:chint-sca-50-60ktl-arcboarderr
IRI
https://solarlattice.org/kb/fc/chint-sca-50-60ktl-arcboarderr
Status
active
Also known as
Arcboard Err, arcboarderr, CPS Arcboard Err
Category
Inverters
Class fault drafted · lead
Production not stated
Clears after a manual reset drafted · lead

Decoded

May indicate arc detection board failure; look at arc fault detection board; confirm with arc fault self-test; do: contact manufacturer service.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same code in other families

Claims

defined_in

c1 drafted · lead CPS-SCA36-50-60KTL fault and troubleshooting

has_event_class

c2 drafted · lead Fault (device stops or needs intervention)

from the Type column

indicates

c3 drafted · lead Arc detection board failure

review note: support check: partial - Arcboard Err name suggests arc board failure and replacement is suggested, but no explicit failure statement.

affects

c4 drafted · lead Arc fault detection board

detected_by

c5 drafted · lead Arc fault self-test

mitigated_by

c6 drafted · lead Contact manufacturer service

Only if the alarm recurs after connector check and arc test.

has_recovery

c7 drafted · lead Manual reset (operator restarts or acknowledges)

Operator checks connector and runs arc test; service if alarm recurs.

review note: support check: partial - Operator actions stated, but manual reset clearing not explicit.