Solar Lattice

Fault codes › CPS › CPS SCA25KTL-DO/US-208

CPS SCA25KTL-208 Protect0180

Code
Protect0180
Shown as
The sampling offset of DCI
Vendor severity
Protection
Page
126
ID
fc:chint-sca-25ktl-208-protect180
IRI
https://solarlattice.org/kb/fc/chint-sca-25ktl-208-protect180
Status
active
Also known as
Protect0180, protect180, CPS Protect0180, The sampling offset of DCI
Category
Inverters
Class fault drafted · lead
Production stops drafted · lead
Clears not stated

Decoded

Reports current sensor offset; look at inverter; do: sensor recalibration, inverter replacement.

What can be behind Current sensor offset

Failure modes that present as the reported condition, and the tests that tell them apart.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same condition on other equipment

CPS
CPS SCA25KTL-480 Protect0180, CPS SCA50-100K-T Protect0180, CPS SCH100-125KTL Protect0180, CPS SCH125KTL-AIO Protect0180, CPS SCH200-250K-T Protect0180, CPS SCH275KTL Protect0180, CPS SCH350KTL Protect0180
SMA
SMA STP-X-US 8501

Same code in other families

Claims

defined_in

c1 drafted · lead CPS SCA25KTL-DO-US-208 User Manual Rev 1.2

has_event_class

c2 drafted · lead Fault (device stops or needs intervention)

from the Type column

reports

c3 drafted · lead Current sensor offset

review note: support check: partial - Passages describe DCI sampling offset, which is approximately a current sensor offset, but the wording differs.

affects

c4 drafted · lead Inverter

review note: support check: partial - Passages refer to the inverter only as the thing to recalibrate or replace; no specific component is stated as affected.

mitigated_by

c5 drafted · lead Sensor recalibration

Applies when the inverter can still start up.

c6 drafted · lead Inverter replacement

When the alarm persists and the inverter cannot start.

has_production_effect

c7 drafted · lead Trip (production stops)

review note: support check: partial - Inability to start up is implied in some cases but a trip is not stated.

applies_to

c8 drafted · lead CPS SCA25KTL-DO/US-208