Solar Lattice

Fault codes › ABB / FIMER › UNO-DM-6.0-TL-PLUS-US

ABB / FIMER UNO-DM-6.0-PLUS E016

Code
E016
Shown as
Inverter Fail
Vendor severity
Error
Page
125
ID
fc:abb-uno-dm-6-0-plus-us-e16
IRI
https://solarlattice.org/kb/fc/abb-uno-dm-6-0-plus-us-e16
Status
active
Also known as
E016, e16, ABB / FIMER E016, Inverter Fail
Category
Inverters
Class fault drafted · lead
Production not stated
Clears after a manual reset drafted · lead

Decoded

May indicate power stage fault; look at inverter bridge; do: inverter restart, contact manufacturer service.

Defined in

The manufacturer's own cause and corrective text is not reproduced here.

Same code in other families

Claims

defined_in

c1 drafted · lead FIMER UNO-DM-6.0-TL-PLUS-US-Q Product Manual RevB

c2 drafted · lead UNO-DM-6.0-TL-PLUS-US Product Manual RevA

has_event_class

c3 drafted · lead Fault (device stops or needs intervention)

from the code prefix

indicates

c4 drafted · lead Power stage fault

review note: support check: partial - The passages describe a problem in the inverter DC/AC circuit, but do not call it a power stage fault.

affects

c5 drafted · lead Inverter bridge

mitigated_by

c6 drafted · lead Inverter restart

c7 drafted · lead Contact manufacturer service

has_recovery

c8 drafted · lead Manual reset (operator restarts or acknowledges)

Power cycle first; contact service if the fault persists afterwards.

review note: support check: partial - Power cycle then contact service is stated, but clearing by manual reset is not stated.

applies_to

c9 drafted · lead UNO-DM-6.0-TL-PLUS-US string inverter

Data