Fault codes › Huawei › Huawei SUN2000-45KTL-US-HV-D0
Huawei SUN2000-45KTL-US-HV-D0 321
- Code
321
- Shown as
- Cabinet Overtempe rature
- Vendor severity
- Major
- Page
- 118
- ID
fc:huawei-sun2000-45ktl-us-hv-d0-321
- IRI
https://solarlattice.org/kb/fc/huawei-sun2000-45ktl-us-hv-d0-321
- Status
- active
- Also known as
- 321, Huawei 321, Cabinet Overtempe rature
- Category
- Inverters
Class
fault drafted · lead
Production
stops drafted · lead
Clears
not stated
Decoded
Reports inverter overtemperature, high ambient temperature; may indicate fan failure; look at cooling fan; do: adequate inverter cooling, contact manufacturer service.
Failure modes that present as the reported condition, and the tests that tell them apart.
Failure modes that present as the reported condition, and the tests that tell them apart.
Defined in
The manufacturer's own cause and corrective text is not reproduced here.
Same condition on other equipment
- ABB / FIMER
- ABB / FIMER PVS-166-175-TL E014, ABB / FIMER PVS-60-TL CODE:05, ABB / FIMER PVS-60-TL E014, ABB / FIMER PVS-60-TL E056, ABB / FIMER TRIO-20.0-27.6-TL CODE:05, ABB / FIMER TRIO-20.0-27.6-TL E014, ABB / FIMER TRIO-20.0-27.6-TL E056, ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:05, ABB / FIMER UNO-DM-3.3-5.0-PLUS E014, ABB / FIMER UNO-DM-3.3-5.0-PLUS E056, ABB / FIMER UNO-DM-6.0-PLUS CODE:05, ABB / FIMER UNO-DM-6.0-PLUS E014, ABB / FIMER UNO-DM-6.0-PLUS E056
- CPS
- CPS SCA25KTL-208 TempOver, CPS SCA25KTL-480 TempOver, CPS SCA36KTL TempOver, CPS SCA50-100K-T Fault6030, CPS SCA50-100K-T Fault6040, CPS SCA50-100K-T Protect0140, CPS SCA50-60KTL TempOver, CPS SCH100-125KTL TempOver, CPS SCH125KTL-AIO TempOver, CPS SCH200-250K-T TempOver, CPS SCH275KTL TempOver, CPS SCH350KTL TempOver
- Canadian Solar
- Canadian Solar 185-255K OV-TEM, Canadian Solar 23-28KTL-CT TempOver, Canadian Solar 25-40K-T480GL01 OV-TEM, Canadian Solar 50-66K-T480GL01 OV-TEM, Canadian Solar 75-100K-T480GL02 OV-TEM
- Fronius
- Fronius Galvo 303, Fronius Galvo 304, Fronius Galvo 517, Fronius Primo 303, Fronius Primo 517, Fronius Symo 303, Fronius Symo 304, Fronius Symo 325, Fronius Symo 517
- Huawei
- Huawei SUN2000-100KTL-USH0 2063, Huawei SUN2000-25-30KTL-US 321
- KACO new energy
- KACO new energy blueplanet TL3 10, KACO new energy blueplanet TL3 100, KACO new energy blueplanet TL3 11, KACO new energy blueplanet TL3 158, KACO new energy blueplanet TL3 58
- SMA
- SMA SB-US-40 8003, SMA SB-US-41 8003, SMA SBSE-US-50 6501, SMA SBSE-US-50 6502, SMA SBSE-US-50 6509, SMA SBSE-US-50 6511, SMA SBSE-US-50 8003, SMA PEAK3-US 6501, SMA PEAK3-US 6511, SMA PEAK3-US 8003, SMA CORE1-US 6502, SMA CORE1-US 8003, SMA STP-TL-US 6501-6511, SMA STP-TL-US 8001, SMA STP-X-US 6501, SMA STP-X-US 6511, SMA SC-CP-XT 6418, SMA SC-CP-XT 6423, SMA SC-CP-XT 6501, SMA SC-CP-XT 6502, SMA SC-CP-XT 6508, SMA SC-CP-XT 6605, SMA SI-US F113, SMA SI-US W110, SMA SI-US W111, SMA SI-US W112, SMA SI-US W114, SMA SI-US W115, SMA SI-US W116, SMA SI-US W137, SMA SI-US W138, SMA SI-US W139, SMA SI-US W140
- Schneider Electric
- Schneider Electric CL125 036, Schneider Electric CL125 037
- Solis
- Solis 1P-4G-US OV-TEM, Solis 3P-5G-US OV-TEM, Solis RHI-1P-HV OV-TEM, Solis S5-GC OV-TEM, Solis S6-EH1P OV-TEM, Solis S6-EH2P LmtByTemp, Solis S6-EH2P OV-TEM, Solis S6-EH3P30-60K LmtByTemp, Solis S6-EH3P30-60K OV-TEM, Solis S6-EH3P75-150K LmtByTemp, Solis S6-EH3P75-150K OV-TEM, Solis S6-GC OV-TEM, Solis S6-GU OV-TEM
- Sungrow
- Sungrow SG-CX-US 036, Sungrow SG-CX-US 037, Sungrow SG200HX 036, Sungrow SG200HX 037, Sungrow SG250HX 36, Sungrow SG250HX 37, Sungrow SG350HX 036, Sungrow SG350HX 037
- Yaskawa Solectria
- Yaskawa Solectria PVI-14-20TL OverTemp, Yaskawa Solectria PVI-25TL-R TempOver, Yaskawa Solectria PVI-TL OverTemp, Yaskawa Solectria SGI-XTM IGBT Overtemp, Yaskawa Solectria SGI-XTM Temp 1 Limiting, Yaskawa Solectria SGI-XTM Temp 2 Limiting, Yaskawa Solectria SGI-XTM Temp 3 Limiting, Yaskawa Solectria XGI-1500-1MW CRIT-6, Yaskawa Solectria XGI-1500-1MW INFO-1, Yaskawa Solectria XGI-1500 CRIT-6, Yaskawa Solectria XGI-1500-DCG CRIT-6, Yaskawa Solectria XGI-1500-DCG INFO-1, Yaskawa Solectria XGI-1500 INFO-1
Same code in other families
Claims
defined_in
c1 drafted · lead
Huawei SUN2000-45KTL-US-HV-D0 User Manual
has_event_class
c2 drafted · lead
Fault (device stops or needs intervention)
from the Type column
reports
c3 drafted · lead
Inverter overtemperature
c4 drafted · lead
High ambient temperature
indicates
c5 drafted · lead
Fan failure
One of the listed causes besides poor ventilation and high ambient temperature
affects
c6 drafted · lead
Cooling fan
mitigated_by
c7 verified · fact
Adequate inverter cooling
verified by: review-workflowverified on: 2026-10-23
c8 drafted · lead
Contact manufacturer service
If ventilation and ambient temperature are within requirements
has_production_effect
c9 drafted · lead
Trip (production stops)
applies_to
c10 drafted · lead
Huawei SUN2000-45KTL-US-HV-D0
Data