FailureMode
Rapid shutdown device failure
- ID
fm:rapid-shutdown-device-failure
- IRI
https://solarlattice.org/kb/fm/rapid-shutdown-device-failure
- Status
- active
- Also known as
- defective RSD, MLPE stuck in bypass mode, JMS-F device no longer producing reference voltage, failed or bypassed MLPE, RSD not activating, RSD failure, TS4 communicating but not producing, Failed or Bypassed MLPE Devices, stuck in bypass mode, defective device
A rapid shutdown device fails when a module-level unit stops working or gets stuck in bypass. The string then loses its correct shutdown voltage, its operating voltage, or both. Typical signs are devices that do not activate when grid power is cut, low string voltage, string mismatches, or units that communicate but do not produce. To check, switch AC off and measure the string in its shutdown state. Expect about 0.6 V per TS4-F unit or about 1 V per JMS-F unit. Then measure Vmp with the system running, because a device stuck in bypass can show a correct safety voltage but a low Vmp. Before suspecting the hardware, confirm that the inverter rapid shutdown mode is set to SunSpec Shutdown. To find the bad unit, keep splitting the string in half or isolate single panel assemblies. Check connectors and housings for heat damage. Use a swap with a known-good device or thermal imaging to back up the result. Photograph the serial number of the faulty device, open a case with the manufacturer, and replace it under warranty. To prevent this, attach each device to its panel before stringing, and check the voltage of each assembly before connecting it into a string.
<!-- review notes
- sentence 3: support check: partial - u1 and u9 give 0.6V per TS4-F and ~1V per JMS-F (u1 says 1V to 2V); the 'about 1 V' is loosely supported and the range is omitted.
-->
Claims
affects
c1 drafted · lead
Module-level rapid shutdown device
presents_as
c2 drafted · lead
Rapid shutdown failure
Devices do not activate when grid power is removed.
c3 drafted · lead
Low string safety voltage proposed
In the shutdown state, string voltage reads below the expected per-device reference voltage times the number of devices.
c4 drafted · lead
Low string operating voltage proposed
The safety voltage can be correct while the operating Vmp is low, which points to an RSD stuck in bypass mode or underperforming.
c5 drafted · lead
MLPE detection failure proposed
TS4-R devices not communicating after detection, or communicating but not producing.
c6 drafted · lead
Hotspot in IR image
Abnormal heat signatures from RSDs; heat alone does not confirm failure.
caused_by
c7 drafted · lead
Installation error
Connecting the device to a panel that is already wired into a string may permanently damage it.
c8 drafted · lead
Electrical overstress
Overvoltage damage when assemblies are strung before each panel has its device attached.
c9 drafted · lead
Poor connector contact
review note: support check: partial - u1 mentions inspecting for damage or poor contact and overheating from poor connections, but does not clearly state poor connector contact causes RSD failure.
detected_by
c10 drafted · lead
MLPE string safety voltage check
c11 drafted · lead
DC voltage measurement
Vmp check across string terminals while the system is running.
c12 verified · fact
Fault localization
Halve the string, or isolate single assemblies, until the faulty device is found.
verified by: review-workflowverified on: 2026-10-24
c13 drafted · lead
Open-circuit voltage measurement
c14 drafted · lead
Infrared thermography
review note: support check: partial - u1 offers thermal imaging as optional diagnostic helpful for identifying faults, but says heat alone does not confirm failure, so detection is only suggestive.
c15 drafted · lead
Visual inspection
c16 verified · fact
Known-good component swap test
verified by: review-workflowverified on: 2026-10-24
distinguished_from
c17 drafted · lead
Rapid shutdown mode misconfiguration — told apart by Inverter settings review
Before blaming a device, confirm that the inverter rapid shutdown mode is set to SunSpec Shutdown. If the setting is correct and the voltage is still low, suspect the device.
review note: support check: partial - u2 says to confirm SunSpec Shutdown setting first, but the passages don't frame it as a differentiator or give the 'setting correct and voltage still low' logic explicitly.
mitigated_by
c18 drafted · lead
MLPE device replacement proposed
c19 drafted · lead
Warranty claim
c20 drafted · lead
Contact manufacturer service
c21 verified · fact
Pre-stringing assembly voltage check proposed
verified by: review-workflowverified on: 2026-10-24
c22 drafted · lead
Proper installation
c23 drafted · lead
DC wiring check
c24 drafted · lead
Wireless range extension
Referenced by
Data