The inverter display check means reading the fault codes, status messages and live measurements on the inverter LCD or in its menus. It helps you work out why the inverter has stopped or raised an alarm. When the inverter is in fault mode, the screen shows the most recent or current fault. The same codes can often be found in the data log of the monitoring system. An arc detection board failure appears as an arc board error, and the inverter will not reconnect to the grid until the board is working again. A real arc fault shows as a separate alarm that must be cleared by hand from the menu. For a temperature sensor fault, first read the temperature on the display. An implausible value, such as a sensor reading of -25C, points to a poorly connected or damaged sensor. A fan that is not working properly triggers a Fan Fail warning on the LCD. Internal power stage or other internal faults appear as internal fault or protection codes. Display readings of grid voltage, grid frequency and PV voltage should be checked against a meter reading, because the measurement circuit itself may be faulty. The display only points to a likely cause. Before touching the fan or other internal parts, switch off at the LCD, disconnect AC and DC, and wait for the stored energy to discharge.

<!-- review notes

Claims

produces

c1 verified · fact Inverter fault code display

In fault mode the LCD shows the most recent or current fault. Fault codes can also be read from the monitoring data log.

verified by: review-workflowverified on: 2026-10-23

c2 verified · fact Arc board error message

If the arc detection board fails, the LCD shows 'arc board err' and the inverter stays off the grid until the board is working again.

verified by: review-workflowverified on: 2026-10-23

c3 verified · fact Arc fault alarm

The arc fault stays latched and must be cleared by hand from the menu.

If an arc fault occurs "Arc Fault Detected!" will be displayed.

verified by: review-workflowverified on: 2026-10-23

c4 verified · fact Implausible sensor temperature value

For TempSensorErr the manuals say to read the temperature on the display first. One manual lists a sensor reading of -25C as a possible cause.

verified by: review-workflowverified on: 2026-10-23review note: support check: partial - The passages support reading the display for TempSensorErr and the -25C cause, but they don't mention a constant low reading pinned at a sensor floor for the signal.

c5 verified · fact Fan fail message

The LCD shows a Fan Fail warning when the fan is not working properly.

verified by: review-workflowverified on: 2026-10-23

c6 verified · fact Grid frequency outside limits

Check the measured frequency on the LCD. If it is within limits, restart the inverter.

verified by: review-workflowverified on: 2026-10-23

c7 verified · fact Grid voltage outside limits

verified by: review-workflowverified on: 2026-10-23